Danfoss VLT AutomationDrive FC 301 Programming Manual page 313

Hide thumbs Also See for VLT AutomationDrive FC 301:
Table of Contents

Advertisement

Parameter Descriptions
3.31.2 43-1* Power Card Status
This parameter group contains read-only information on
the power card status. All parameters in this group are
arrays:
[0]: Power card 1 (the master power card in a
parallel frequency converter, or the only power
card in a frequency converter with a single
inverter section).
[1]: Power card 2 (inverter connection in a parallel
frequency converter).
[2]: Power card 3 (inverter connection in a parallel
frequency converter).
[3]: Power card 4 (inverter connection in a parallel
frequency converter).
[4]: Power card 5 (rectifier connection in a parallel
frequency converter).
[5]: Power card 6 (rectifier connection in a parallel
frequency converter).
[6]: Power card 7 (rectifier connection in a parallel
frequency converter).
[7]: Power card 8 (rectifier connection in a parallel
frequency converter).
43-10 HS Temp. ph.U
Range:
Function:
NOTICE
0 °C
[-128 -
*
127 °C]
This parameter is valid for FC
302 only.
Shows the heat sink temperature at
the location of the phase U IGBT
power module. This measurement is
not available in all enclosure sizes.
Parameter 16-34 Heatsink Temp. uses
the value in this parameter.
43-11 HS Temp. ph.V
Range:
Function:
NOTICE
0 °C
[-128 -
*
127 °C]
This parameter is valid for FC
302 only.
Shows the heat sink temperature at
the location of the phase V IGBT
power module. This measurement is
not available in all enclosure sizes.
Parameter 16-34 Heatsink Temp. uses
the value in this parameter.
M0013101
Programming Guide
43-12 HS Temp. ph.W
Range:
0 °C
*
43-13 PC Fan A Speed
Range:
0 RPM
*
43-14 PC Fan B Speed
Range:
0 RPM
*
Danfoss A/S © 10/2019 All rights reserved.
Function:
NOTICE
[-128 -
127 °C]
This parameter is valid for FC
302 only.
Shows the heat sink temperature at
the location of the phase W IGBT
power module. This measurement is
not available in all enclosure sizes.
Parameter 16-34 Heatsink Temp. uses
the value in this parameter.
Function:
NOTICE
[0 - 65535
RPM]
This parameter is valid for FC
302 only.
Shows the measured speed of fan A
on the power card. Each power
card has up to 3 fan connections.
Place the fan in the frequency
converter according to the
operating guide. A typical placement
for fan A is in the backchannel (the
external fan).
The value of this parameter is:
The actual fan speed
when there is a DC fan in
the frequency converter.
Relative speed when there
is an AC fan in the
frequency converter.
Function:
NOTICE
[0 - 65535
RPM]
This parameter is valid for FC
302 only.
Shows the measured speed of fan B
on the power card. Each power
card has up to 3 fan connections.
Place the fan in the frequency
converter according to the
operating guide. A typical placement
for fan B is on the enclosure door
(the internal fan).
The value of this parameter is:
3