Parameter Descriptions
8-17 Configurable Alarm and Warningword
The configurable alarm and warning word has 16 bits (0–15).
Each of those bits can be configured to any of the following
options.
Option:
3
3
[10068]
Safe stop
alarm
[10069]
Powercard
temp alarm
[10073]
Safestop auto
restart alarm
[10074]
PTC thermistor
alarm
[10075]
Illegal profile
alarm
[10078]
Tracking error
alarm
[10079]
Illegal PS
config alarm
[10081]
CSIV corrupt
alarm
[10082]
CSIV param
error alarm
[10084]
No safety
option alarm
[10090]
Feedback
monitor alarm
[10091]
AI54 settings
alarm
[10164]
ATEX ETR
current lim
alarm
[10166]
ATEX ETR freq
limit alarm
8-19 Product Code
Range:
Size
related
2147483647 ]
*
3.9.3 8-3* FC Port Settings
8-30 Protocol
Option:
[0]
FC
*
[1]
FC MC
[2]
Modbus RTU
192
Function:
Function:
[0 -
Select 0 to read out the actual
fieldbus product code according to
the mounted fieldbus option. Select
1 to read out the actual vendor ID.
Function:
Select the protocol to be used.
Changing protocol is not effective
until after powering off the
frequency converter.
Danfoss A/S © 10/2019 All rights reserved.
®
VLT
AutomationDrive FC 301/302
8-31 Address
Range:
1
*
8-32 FC Port Baud Rate
Option:
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
8-33 Parity / Stop Bits
Option:
[0]
*
[1]
[2]
[3]
8-34 Estimated cycle time
Range:
0 ms
*
8-35 Minimum Response Delay
Range:
10 ms
*
8-36 Max Response Delay
Range:
Size
related
*
Function:
[ 1 - 247 ]
Enter the address for the frequency
converter (standard) port.
Valid range: Depends on selected
protocol.
Function:
2400 Baud
Baud rate selection for the FC
(standard) port.
4800 Baud
9600 Baud
19200 Baud
38400 Baud
57600 Baud
76800 Baud
115200 Baud
Function:
Even Parity, 1
Stop Bit
Odd Parity, 1
Stop Bit
No Parity, 1
Stop Bit
No Parity, 2
Stop Bits
Function:
[0 - 1000000
In noisy environments, the interface
ms]
may be blocked due to overload or
bad frames. This parameter specifies
the time between 2 consecutive
frames on the network. If the
interface does not detect valid
frames in that time, it flushes the
receive buffer.
Function:
[ 1 - 10000
Specify the minimum delay time
ms]
between receiving a request and
transmitting a response. This is
used for overcoming modem
turnaround delays.
Function:
[ 11 - 10001
Specify the maximum allowed delay
ms]
time between transmitting a
request and receiving a response. If
a response from the frequency
M0013101