Parameter Descriptions
3.16.5 16-6* Inputs and Outputs
16-60 Digital Input
Range:
Function:
0
[ 0 - 65535 ]
View the signal states from the
*
active digital inputs. Example: Input
18 corresponds to bit number 5, 0
= no signal, 1 = connected signal.
Bit 6 works in the opposite way, on
= 0, off = 1 (Safe Torque Off input).
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10–
63
Table 3.33 Active Digital Inputs
Illustration 3.68 Relay Settings
M0013101
Programming Guide
[0]
[1]
0
Digital input terminal
33.
Digital input terminal
32.
[0]
Digital input terminal
[1]
29.
Digital input terminal
27.
0
Digital input terminal
19.
Digital input terminal
18.
Digital input terminal
0
37.
®
Digital input VLT
General Purpose I/O
MCB 101 terminal X30/4.
®
Digital input VLT
General Purpose I/O
MCB 101 terminal X30/3.
0
®
Digital input VLT
General Purpose I/O
MCB 101 terminal X30/2.
Reserved for future
terminals.
0
0
0
Danfoss A/S © 10/2019 All rights reserved.
16-61 Terminal 53 Switch Setting
View the setting of input terminal 53.
Option:
Function:
Current
*
Voltage
16-62 Analog Input 53
Range:
Function:
[-20 - 20 ]
View the actual value at input 53.
*
16-63 Terminal 54 Switch Setting
View the setting of input terminal 54.
Option:
Function:
Current
*
Voltage
16-64 Analog Input 54
Range:
Function:
[-20 - 20 ]
View the actual value at input 54.
*
16-65 Analog Output 42 [mA]
Range:
Function:
[0 - 30 ]
View the actual value at output 42
*
in mA. The value shown reflects the
selection in parameter 6-50 Terminal
42 Output.
16-66 Digital Output [bin]
Range:
Function:
[0 - 15 ]
View the binary value of all digital
*
outputs.
16-67 Freq. Input #29 [Hz]
Range:
Function:
[0 - 130000 ]
View the actual frequency rate on
*
terminal 29.
16-68 Freq. Input #33 [Hz]
Range:
Function:
[0 - 130000 ]
View the actual value of the
*
frequency applied at terminal 33 as
an impulse input.
16-69 Pulse Output #27 [Hz]
Range:
Function:
[0 - 40000 ]
View the actual value of pulses
*
applied to terminal 27 in digital
output mode.