Parameter Descriptions
35-44 Term. X48/2 Low Ref./Feedb. Value
Range:
Function:
current set in parameter 35-42 Term.
X48/2 Low Current.
35-45 Term. X48/2 High Ref./Feedb. Value
Range:
Function:
100
[-999999.999
Enter the reference or feedback
Reference-
- 999999.999
value (in RPM, Hz, bar, and so on)
FeedbackU
Reference-
that corresponds to the voltage or
nit
FeedbackUnit]
current set in parameter 35-43 Term.
*
X48/2 High Current.
35-46 Term. X48/2 Filter Time Constant
Range:
Function:
0.001 s
[0.001 - 10 s] Enter the filter time constant. This is
*
a first-order digital low-pass filter
time constant for suppressing
electrical noise in terminal X48/2. A
high time constant value improves
dampening but also increases the
time delay through the filter.
3.28 Parameters: 36-** Programmable I/O
Option
Parameters for configuring VLT
115.
Parameters in this group are active only when VLT
Programmable I/O MCB 115 is installed.
3.28.1 36-0* I/O Mode
Use the parameters in this group to configure the mode of
®
inputs and outputs of VLT
Programmable I/O MCB 115.
Terminals can be programmed to provide voltage, current,
or digital output.
36-00 Terminal X49/1 Mode
Option:
Function:
[0]
Current
[1]
Voltage
*
[2]
Pt 1000 [°C]
[3]
Pt 1000 [°F]
[4]
Ni 1000 [°C]
[5]
Ni 1000 [°F]
36-01 Terminal X49/3 Mode
Option:
Function:
[0]
Current
[1]
Voltage
*
[2]
Pt 1000 [°C]
[3]
Pt 1000 [°F]
[4]
Ni 1000 [°C]
[5]
Ni 1000 [°F]
M0013101
Programming Guide
®
Programmable I/O MCB
®
Danfoss A/S © 10/2019 All rights reserved.
36-02 Terminal X49/5 Mode
Option:
Function:
[0]
Current
[1]
Voltage
*
[2]
Pt 1000 [°C]
[3]
Pt 1000 [°F]
[4]
Ni 1000 [°C]
[5]
Ni 1000 [°F]
36-03 Terminal X49/7 Mode
Select the output mode of analog terminal X49/7.
Option:
Function:
[0]
Voltage 0-10V
*
[1]
Voltage 2-10V
[2]
Current
0-20mA
[3]
Current
4-20mA
[4]
Digital
36-04 Terminal X49/9 Mode
Select the output mode of analog terminal X49/9.
Option:
Function:
[0]
Voltage 0-10V
*
[1]
Voltage 2-10V
[2]
Current
0-20mA
[3]
Current
4-20mA
[4]
Digital
36-05 Terminal X49/11 Mode
Select the output mode of analog terminal X49/11.
Option:
Function:
[0]
Voltage 0-10V
*
[1]
Voltage 2-10V
[2]
Current
0-20mA
[3]
Current
4-20mA
[4]
Digital
36-10 Terminal X49/1 Low Voltage
Range:
Function:
0.07 V
[ 0 - par.
*
36-12 V]
36-11 Terminal X49/1 Low Current
Range:
Function:
4 mA
[ 0 - par.
*
36-13 mA]
3
3
297