Parameter Lists
0-76
DST/Summertime Start
0-77
DST/Summertime End
0-79
Clock Fault
0-81
Working Days
0-82
Additional Working Days
0-83
Additional Non-Working Days
0-84
Time for Fieldbus
0-85
Summer Time Start for Fieldbus
0-86
Summer Time End for Fieldbus
0-89
Date and Time Readout
5
5
Table 5.3
5.2.2 1-** Load and Motor
Par.
Parameter description
No. #
1-0* General Settings
1-00
Configuration Mode
1-01
Motor Control Principle
1-02
Flux Motor Feedback Source
1-03
Torque Characteristics
1-04
Overload Mode
1-05
Local Mode Configuration
1-06
Clockwise Direction
1-07
Motor Angle Offset Adjust
1-1* Special Settings
1-10
Motor Construction
1-11
Motor Model
1-14
Damping Gain
1-15
Low Speed Filter Time Const.
1-16
High Speed Filter Time Const.
1-17
Voltage filter time const.
1-18
Min. Current at No Load
1-2* Motor Data
1-20
Motor Power [kW]
1-21
Motor Power [HP]
1-22
Motor Voltage
1-23
Motor Frequency
1-24
Motor Current
1-25
Motor Nominal Speed
1-26
Motor Cont. Rated Torque
1-29
Automatic Motor Adaptation (AMA)
1-3* Adv. Motor Data
1-30
Stator Resistance (Rs)
1-31
Rotor Resistance (Rr)
1-33
Stator Leakage Reactance (X1)
1-34
Rotor Leakage Reactance (X2)
1-35
Main Reactance (Xh)
1-36
Iron Loss Resistance (Rfe)
1-37
d-axis Inductance (Ld)
1-38
q-axis Inductance (Lq)
1-39
Motor Poles
322
®
VLT
AutomationDrive FC 301/302
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
0 N/A
0 N/A
0 N/A
0 N/A
Default value
ExpressionLimit
ExpressionLimit
[1] 24V encoder 32/33
[0] Constant torque
[0] High torque
[2] As mode par 1-00
[0] Normal
[0] Manual
[0] Asynchron
ExpressionLimit
140 %
ExpressionLimit
ExpressionLimit
ExpressionLimit
0 %
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
[0] Off
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
Danfoss A/S © 10/2019 All rights reserved.
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
4-set-up
FC 302
Change
only
during
operation
All set-ups
TRUE
All set-ups
FALSE
All set-ups
x
FALSE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
x
FALSE
All set-ups
FALSE
All set-ups
x
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
x
FALSE
All set-ups
x
FALSE
All set-ups
FALSE
TimeO
0
fDay
TimeO
0
fDay
-
Uint8
-
Uint8
TimeO
0
fDay
TimeO
0
fDay
0
Uint32
0
Uint32
0
Uint32
VisStr[
0
25]
Conver-
Type
sion index
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
0
Int16
-2
Uint16
-2
Uint16
-3
Uint16
0
Uint16
1
Uint32
-2
Uint32
0
Uint16
0
Uint16
-2
Uint32
67
Uint16
-1
Uint32
-
Uint8
-4
Uint32
-4
Uint32
-4
Uint32
-4
Uint32
-4
Uint32
-3
Uint32
-4
Int32
-6
Int32
0
Uint8
M0013101