Parameter Descriptions
30-04 Wobble Jump Frequency [Hz]
Range:
0 Hz
*
3
3
30-05 Wobble Jump Frequency [%]
Range:
0 %
*
30-06 Wobble Jump Time
Range:
Size
related
5.000 s]
*
30-07 Wobble Sequence Time
Range:
10 s
*
30-08 Wobble Up/ Down Time
Range:
5 s
*
30-09 Wobble Random Function
Option:
[0]
Off
*
[1]
On
30-10 Wobble Ratio
Range:
1
*
280
Function:
[ 0 - 20.0 Hz]
The jump frequency is used to
compensate for the inertia in the
traverse system. If a jump in the
output frequency is required at the
boundaries of the wobble
sequence, the frequency jump is set
in this parameter. If the traverse
system has a very high inertia, a
high jump frequency may create a
torque limit warning or trip or an
overvoltage warning or trip. This
parameter can only be changed in
stop mode.
Function:
[0 - 100 %]
The jump frequency can also be
expressed as percentage of the
center frequency. The function is
the same as for
parameter 30-04 Wobble Jump
Frequency [Hz].
Function:
[ 0.005 -
This parameter determines the
slope of the jump ramp at the
maximum and minimum wobble
frequency.
Function:
[1 - 1000 s]
This parameter determines the
wobble sequence period. This
parameter can only be changed in
stop mode.
Wobble time = t
up
Function:
[0.1 - 1000 s] Defines the individual up and down
times for each wobble cycle.
Function:
Function:
[0.1 - 10 ]
If the ratio 0.1 is selected: t
10 times greater than t
Danfoss A/S © 10/2019 All rights reserved.
®
VLT
AutomationDrive FC 301/302
30-10 Wobble Ratio
Range:
3.22.2 Center Frequency
Use parameter group 3-1* References to set the center
frequency.
30-11 Wobble Random Ratio Max.
Range:
10
*
30-12 Wobble Random Ratio Min.
Range:
0.1
*
30-19 Wobble Delta Freq. Scaled
Range:
0 Hz
*
3.22.3 30-2* Adv. Start Adjust
30-20 High Starting Torque Time [s]
Range:
Size
related
*
+ t
down
30-21 High Starting Torque Current [%]
Range:
Size
related
*
is
down
.
up
Function:
If the ratio 10 is selected: t
times greater than t
Function:
[ par. 17-53 -
Enter the maximum allowed
10 ]
wobble ratio.
Function:
[ 0.1 - par.
Enter the minimum allowed wobble
30-11 ]
ratio.
Function:
[0 - 1000 Hz] Readout parameter. View the actual
wobble delta frequency after
scaling has been applied.
Function:
NOTICE
[0 - 60 s]
This parameter is available for
FC 302 only.
High starting torque time for PM
motor in flux control principle
without feedback.
Function:
NOTICE
[ 0 - 200.0 %]
This parameter is available for
FC 302 only.
High starting torque current for PM
+
motor in VVC
and flux mode
without feedback.
is 10
up
.
down
M0013101