Parameter Descriptions
13-52 SL Controller Action
Option:
[120]
Start Homing
3
3
[121]
Stop Homing
[122]
Enable
Reference
[123]
Disable
Reference
[124]
Relative
Position
[125]
Absolute
Position
226
®
VLT
AutomationDrive FC 301/302
Function:
NOTICE
This option is available only
with software version 48.20
and newer.
Activates the homing mode and
starts the homing function selected
in parameter 17-80 Homing Function.
Must remain active until the
homing is completed otherwise the
homing is aborted.
NOTICE
This option is available only
with software version 48.20
and newer.
Deactivates the homing mode, an
active homing function is aborted if
the homing is not completed.
NOTICE
This option is available only
with software version 48.20
and newer.
Sets the enable reference mode.
NOTICE
This option is available only
with software version 48.20
and newer.
Disables the enable reference
mode.
NOTICE
This option is available only
with software version 48.20
and newer.
Selects the relative position mode
instead of the absolute position
mode.
NOTICE
This option is available only
with software version 48.20
and newer.
Selects the absolute position mode
instead of the relative position
mode.
Danfoss A/S © 10/2019 All rights reserved.
13-52 SL Controller Action
Option:
Function:
NOTICE
[126]
Activate Touch
This option is available only
with software version 48.20
and newer.
Activates the touch probe
positioning mode.
NOTICE
[127]
Deactivate
Touch
This option is available only
with software version 48.20
and newer.
Deactivates the touch probe
positioning mode.
NOTICE
[128]
Target Inverse
This option is available only
with software version 48.20
and newer.
Changes the sign of the active
target position value.
NOTICE
[129]
Target
This option is available only
with software version 48.20
and newer.
The active target position is not
changed.
NOTICE
[130]
Act. Speed
Mode
This option is available only
with software version 48.20
and newer.
Activates the speed mode when
option [9] Positioning or option
[10] Synchronizationis selected in
parameter 1-00 Configuration Mode.
NOTICE
[131]
Deact. Speed
Mode
This option is available only
with software version 48.20
and newer.
Deactivates the speed mode and
activates the option selected in
parameter 1-00 Configuration Mode.
M0013101