Parameter Descriptions
13-42 Logic Rule Boolean 2
Option:
Function:
NOTICE
[223]
On Target
This option is available only
with software version 48.20
and newer.
Positioning is completed and the
on-target signal is sent when the
actual position is within
parameter 3-05 On Reference
Window for the duration of
parameter 3-09 On Target Time and
the actual speed does not exceed
parameter 3-05 On Reference
Window.
NOTICE
[224]
Position Error
This option is available only
with software version 48.20
and newer.
The position error exceeds the
value in parameter 4-71 Maximum
Position Error for the time set in
parameter 4-72 Position Error
Timeout.
NOTICE
[225]
Position Limit
This option is available only
with software version 48.20
and newer.
The position is outside the limits
set in parameter 3-06 Minimum
Position and
parameter 3-07 Maximum Position.
NOTICE
[226]
Touch on
Target
This option is available only
with software version 48.20
and newer.
Target position is reached in touch
probe position mode.
NOTICE
[227]
Touch
Activated
This option is available only
with software version 48.20
and newer.
Touch probe positioning active. The
frequency converter monitors the
touch probe sensor input.
M0013101
Programming Guide
13-43 Logic Rule Operator 2
Option:
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
13-44 Logic Rule Boolean 3
Array [6]
Option:
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
Danfoss A/S © 10/2019 All rights reserved.
Function:
nd
Select the 2
logical operator to be
used on the boolean input
calculated in:
Parameter 13-40 Logic Rule
Boolean 1.
Parameter 13-41 Logic Rule
Operator 1.
Parameter 13-42 Logic Rule
Boolean 2.
[13-44] signifies the boolean input
of parameter 13-44 Logic Rule
Boolean 3.
[13-40/13-42] signifies the boolean
input calculated in:
Parameter 13-40 Logic Rule
Boolean 1.
Parameter 13-41 Logic Rule
Operator 1.
Parameter 13-42 Logic Rule
Boolean 2.
DISABLED
AND
OR
AND NOT
OR NOT
NOT AND
NOT OR
NOT AND NOT
NOT OR NOT
Function:
False
rd
Select the 3
boolean (true or false)
input for the selected logic rule.
See parameter 13-01 Start Event
(options [0] False–[61] Logic rule 5)
and parameter 13-02 Stop Event
(options [70] SL Time-out 3–[75]
Start command given) for more
information.
True
Running
In range
On reference
Torque limit
Current Limit
Out of current
range
Below I low
Above I high
3
3
219