Parameter Lists
4-53
Warning Speed High
4-54
Warning Reference Low
4-55
Warning Reference High
4-56
Warning Feedback Low
4-57
Warning Feedback High
4-58
Missing Motor Phase Function
4-59
Motor Check At Start
4-6* Speed Bypass
4-60
Bypass Speed From [RPM]
4-61
Bypass Speed From [Hz]
4-62
Bypass Speed To [RPM]
4-63
Bypass Speed To [Hz]
4-7* Position Monitor
4-70
Position Error Function
4-71
Maximum Position Error
4-72
Position Error Timeout
4-73
Position Limit Function
4-74
Start Fwd/Rev Function
4-75
Touch Timout
4-8* Power Limit
4-80
Power Limit Func. Motor Mode
4-81
Power Limit Func. Generator Mode
4-82
Power Limit Motor Mode
4-83
Power Limit Generator Mode
4-9* Directional Limits
4-90
Directional Limit Mode
4-91
Positive Speed Limit [RPM]
4-92
Positive Speed Limit [Hz]
4-93
Negative Speed Limit [RPM]
4-94
Negative Speed Limit [Hz]
4-95
Positive Torque limit
4-96
Negative Torque limit
5.2.6 5-** Digital In/Out
Par.
Parameter description
No. #
5-0* Digital I/O mode
5-00
Digital I/O Mode
5-01
Terminal 27 Mode
5-02
Terminal 29 Mode
5-1* Digital Inputs
5-10
Terminal 18 Digital Input
5-11
Terminal 19 Digital Input
5-12
Terminal 27 Digital Input
5-13
Terminal 29 Digital Input
5-14
Terminal 32 Digital Input
5-15
Terminal 33 Digital Input
5-16
Terminal X30/2 Digital Input
5-17
Terminal X30/3 Digital Input
5-18
Terminal X30/4 Digital Input
5-19
Terminal 37 Safe Stop
5-20
Terminal X46/1 Digital Input
5-21
Terminal X46/3 Digital Input
5-22
Terminal X46/5 Digital Input
5-23
Terminal X46/7 Digital Input
5-24
Terminal X46/9 Digital Input
5-25
Terminal X46/11 Digital Input
5-26
Terminal X46/13 Digital Input
5-3* Digital Outputs
M0013101
Programming Guide
ExpressionLimit
All set-ups
-999999.999 N/A
All set-ups
999999.999 N/A
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
[0] Off
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
[0] Disabled
All set-ups
1000 CustomReadoutUnit2
All set-ups
0.100 s
All set-ups
[3] Abs. Pos. Mode Stop
All set-ups
[0] Stop
All set-ups
6000.0 s
All set-ups
[0] Disabled
All set-ups
[0] Disabled
All set-ups
100.0 %
All set-ups
100.0 %
All set-ups
[0] Disabled
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
Default value
4-set-up
[0] PNP
All set-ups
[0] Input
All set-ups
[0] Input
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
1 set-up
[0] No operation
All set-ups
[0] No operation
All set-ups
[0] No operation
All set-ups
[0] No operation
All set-ups
[0] No operation
All set-ups
[0] No operation
All set-ups
[0] No operation
All set-ups
Danfoss A/S © 10/2019 All rights reserved.
TRUE
67
TRUE
-3
TRUE
-3
TRUE
-3
TRUE
-3
TRUE
-
TRUE
-
TRUE
67
TRUE
-1
TRUE
67
TRUE
-1
TRUE
-
TRUE
0
TRUE
-3
TRUE
-
TRUE
-
TRUE
-1
x
TRUE
-
x
TRUE
-
x
TRUE
-1
x
TRUE
-1
TRUE
-
TRUE
67
TRUE
-1
TRUE
67
TRUE
-1
TRUE
-1
TRUE
-1
FC 302
Change
Conver-
only
during
sion index
operation
FALSE
-
TRUE
-
x
TRUE
-
TRUE
-
TRUE
-
TRUE
-
x
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
Uint16
Int32
Int32
Int32
Int32
Uint8
Uint8
Uint16
Uint16
Uint16
Uint16
5
5
Uint8
Int32
Uint16
Uint8
Uint8
Uint16
Uint8
Uint8
Uint16
Uint16
Uint8
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Type
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
327