Parameter Descriptions
5-15 Terminal 33 Digital Input
Option:
[23]
Set-up select
bit 0
[24]
Set-up select
3
3
bit 1
[28]
Catch up
[29]
Slow down
[30]
Counter input
[31]
Pulse edge
triggered
[32]
Pulse time
based
[34]
Ramp bit 0
[35]
Ramp bit 1
[44]
Restart Drive
[51]
External
Interlock
[55]
DigiPot
increase
[56]
DigiPot
decrease
[57]
DigiPot clear
[58]
DigiPot Hoist
[60]
Counter A (up)
[61]
Counter A
(down)
[62]
Reset Counter
A
[63]
Counter B (up)
[64]
Counter B
(down)
[65]
Reset Counter
B
[70]
Mech. Brake
Feedb.
[71]
Mech. Brake
Feedb. Inv.
[72]
PID error
inverse
[73]
PID reset I
part
[74]
PID enable
[75]
MCO Specific
[78]
Reset Maint.
Word
[80]
PTC Card 1
[91]
Profidrive
OFF2
[92]
Profidrive
OFF3
[94]
Light Load
Detection
[95]
Evacuation
mode
128
®
VLT
AutomationDrive FC 301/302
Function:
Danfoss A/S © 10/2019 All rights reserved.
5-15 Terminal 33 Digital Input
Option:
Function:
[96]
Mains Loss
[97]
Mains Loss
Inverse
[98]
Start edge
triggered
[100]
Safe Option
Reset
[106]
Set Master
Home
[107]
Target Inverse
[108]
Enable Mast.
Offset
[109]
Enable Vir.
Master
[110]
Start Homing
[111]
Activate Touch
[112]
Relative
Position
[113]
Enable
Reference
[114]
Sync. to Pos.
Mode
[115]
Home Sensor
[116]
Home Sensor
Inv.
[117]
Touch Sensor
[118]
Touch Sensor
Inv.
[119]
Speed Mode
[122]
Position Vir.
Master
[123]
Master Marker
[124]
Master Marker
Inv.
[125]
Follower
Marker
[126]
Follow. Marker
Inv.
[231]
Power Limit
Mot.
[232]
Power Limit
Gen.
[233]
Power Limit
Both
[234]
Light Load
+Evacuation
5-16 Terminal X30/2 Digital Input
Option:
Function:
[0]
No operation
This parameter is active when
option module VLT
Purpose I/O MCB 101 is installed in
the frequency converter. Functions
®
General
M0013101