Parameter Descriptions
13-02 Stop Event
Select the boolean (true or false) input to deactivate smart logic
control.
Option:
Function:
alarm 166, ATEX ETR freq.lim.alarm is
active, the output is 1.
[92]
ATEX ETR freq.
Available if parameter 1-90 Motor
warning
Thermal Protection is set to [20]
ATEX ETR or [21] Advanced ETR. If
alarm 163, ATEX ETR cur.lim.warning
is active, the output is 1.
[93]
ATEX ETR freq.
Available if parameter 1-90 Motor
alarm
Thermal Protection is set to [20]
ATEX ETR or [21] Advanced ETR. If
warning 165, ATEX ETR
freq.lim.warning is active, the output
is 1.
[94]
RS Flipflop 0
See parameter group 13-1*
Comparators.
[95]
RS Flipflop 1
See parameter group 13-1*
Comparators.
[96]
RS Flipflop 2
See parameter group 13-1*
Comparators.
[97]
RS Flipflop 3
See parameter group 13-1*
Comparators.
[98]
RS Flipflop 4
See parameter group 13-1*
Comparators.
[99]
RS Flipflop 5
See parameter group 13-1*
Comparators.
[100]
RS Flipflop 6
See parameter group 13-1*
Comparators.
[101]
RS Flipflop 7
See parameter group 13-1*
Comparators.
[102]
Relay 1
[103]
Relay 2
[104]
Relay 3
X47/VLT
113.
[105]
Relay 4
X47/VLT
113.
[106]
Relay 5
X47/VLT
113.
[107]
Relay 6
X47/VLT
113.
[108]
Relay 7
X34/VLT
[109]
Relay 8
X34/VLT
[110]
Relay 9
X34/VLT
[222]
Homing Ok
[223]
On Target
[224]
Position Error
M0013101
Programming Guide
®
Extended Relay Card MCB
®
Extended Relay Card MCB
®
Extended Relay Card MCB
®
Extended Relay Card MCB
®
Relay Card MCB 105.
®
Relay Card MCB 105.
®
Relay Card MCB 105.
Danfoss A/S © 10/2019 All rights reserved.
13-02 Stop Event
Select the boolean (true or false) input to deactivate smart logic
control.
Option:
Function:
[225]
Position Limit
[226]
Touch on
Target
[227]
Touch
Activated
13-03 Reset SLC
Option:
Function:
[0]
Do not reset
Retain programmed settings in
*
SLC
parameter group 13-** Smart Logic.
[1]
Reset SLC
Reset all parameters in parameter
group 13-** Smart Logic to default
settings.
3.13.2 13-1* Comparators
Comparators are used for comparing continuous variables
(that is output frequency, output current, analog input, and
so on) to fixed preset values.
Par. 13-11
Comparator Operator
Par. 13-10
Comparator Operand
=
TRUE longer than.
Par. 13-12
Comparator Value
. . .
. . .
Illustration 3.54 Comparators
There are digital values that are compared to fixed time
values. See the explanation in parameter 13-10 Comparator
Operand. Comparators are evaluated once in each scan
interval. Use the result (true or false) directly. All
parameters in this parameter group are array parameters
with index 0–9. Select index 0 to program comparator 0,
select index 1 to program comparator 1, and so on.
13-10 Comparator Operand
Option:
Function:
Options [1] Reference % to [31]
Counter B are variables which are
compared based on their values.
Options [50] FALSE to [186] Drive in
auto mode are digital values (true/
false) where the comparison is
based on the amount of time
during which they are set to true or
false. See
parameter 13-11 Comparator
Operator.
3
3
205

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vlt automationdrive fc 302

Table of Contents