Parameter Lists
12-99 Media Counters
5.2.13 13-** Smart Logic
Par.
Parameter description
No. #
13-0* SLC Settings
13-00 SL Controller Mode
13-01 Start Event
13-02 Stop Event
13-03 Reset SLC
13-1* Comparators
13-10 Comparator Operand
13-11 Comparator Operator
13-12 Comparator Value
13-1* RS Flip Flops
13-15 RS-FF Operand S
13-16 RS-FF Operand R
13-2* Timers
13-20 SL Controller Timer
13-4* Logic Rules
13-40 Logic Rule Boolean 1
13-41 Logic Rule Operator 1
13-42 Logic Rule Boolean 2
13-43 Logic Rule Operator 2
13-44 Logic Rule Boolean 3
13-5* States
13-51 SL Controller Event
13-52 SL Controller Action
13-9* User Defined Alerts
13-90 Alert Trigger
13-91 Alert Action
13-92 Alert Text
13-9* User Defined Readouts
13-97 Alert Alarm Word
13-98 Alert Warning Word
13-99 Alert Status Word
5.2.14 14-** Special Functions
Par.
Parameter description
No. #
14-0* Inverter Switching
14-00 Switching Pattern
14-01 Switching Frequency
14-03 Overmodulation
14-04 Acoustic Noise Reduction
14-06 Dead Time Compensation
14-1* Mains Failure
14-10 Mains Failure
14-11 Mains Fault Voltage Level
14-12 Response to Mains Imbalance
M0013101
Programming Guide
0 N/A
All set-ups
Default value
4-set-up
ExpressionLimit
2 set-ups
ExpressionLimit
2 set-ups
ExpressionLimit
2 set-ups
[0] Do not reset SLC
All set-ups
ExpressionLimit
2 set-ups
ExpressionLimit
2 set-ups
ExpressionLimit
2 set-ups
ExpressionLimit
2 set-ups
ExpressionLimit
2 set-ups
ExpressionLimit
1 set-up
ExpressionLimit
2 set-ups
ExpressionLimit
2 set-ups
ExpressionLimit
2 set-ups
ExpressionLimit
2 set-ups
ExpressionLimit
2 set-ups
ExpressionLimit
2 set-ups
ExpressionLimit
2 set-ups
[0] False
2 set-ups
[0] Info
2 set-ups
ExpressionLimit
2 set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
Default value
4-set-up
[1] SFAVM
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
[0] Off
All set-ups
[1] On
All set-ups
[0] No function
All set-ups
ExpressionLimit
All set-ups
[0] Trip
All set-ups
Danfoss A/S © 10/2019 All rights reserved.
TRUE
0
FC 302
Change
Conver-
only
during
sion index
operation
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-3
TRUE
-
TRUE
-
TRUE
-3
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
0
FALSE
0
FALSE
0
FALSE
0
FC 302
Change
Conver-
only
during
sion index
operation
TRUE
-
TRUE
-
FALSE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
0
TRUE
-
Uint32
Type
Uint8
Uint8
Uint8
5
5
Uint8
Uint8
Uint8
Int32
Uint8
Uint8
TimD
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
VisStr[
20]
Uint32
Uint32
Uint32
Type
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint16
Uint8
335