Danfoss VLT AutomationDrive FC 301 Programming Manual page 335

Hide thumbs Also See for VLT AutomationDrive FC 301:
Table of Contents

Advertisement

Parameter Lists
10-07 Readout Bus Off Counter
10-1* DeviceNet
10-10 Process Data Type Selection
10-11 Process Data Config Write
10-12 Process Data Config Read
10-13 Warning Parameter
10-14 Net Reference
10-15 Net Control
10-2* COS Filters
10-20 COS Filter 1
10-21 COS Filter 2
10-22 COS Filter 3
10-23 COS Filter 4
10-3* Parameter Access
10-30 Array Index
10-31 Store Data Values
10-32 Devicenet Revision
10-33 Store Always
10-34 DeviceNet Product Code
10-39 Devicenet F Parameters
10-5* CANopen
10-50 Process Data Config Write.
10-51 Process Data Config Read.
5.2.12 12-** Ethernet
Par.
Parameter description
No. #
12-0* IP Settings
12-00 IP Address Assignment
12-01 IP Address
12-02 Subnet Mask
12-03 Default Gateway
12-04 DHCP Server
12-05 Lease Expires
12-06 Name Servers
12-07 Domain Name
12-08 Host Name
12-09 Physical Address
12-1* Ethernet Link Parameters
12-10 Link Status
12-11 Link Duration
12-12 Auto Negotiation
12-13 Link Speed
12-14 Link Duplex
12-18 Supervisor MAC
M0013101
Programming Guide
0 N/A
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
0 N/A
All set-ups
[0] Off
2 set-ups
[0] Off
2 set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
2 set-ups
[0] Off
All set-ups
ExpressionLimit
All set-ups
[0] Off
1 set-up
ExpressionLimit
1 set-up
0 N/A
All set-ups
ExpressionLimit
2 set-ups
ExpressionLimit
2 set-ups
Default value
4-set-up
ExpressionLimit
2 set-ups
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
2 set-ups
ExpressionLimit
All set-ups
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
[0] No Link
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
2 set-ups
ExpressionLimit
2 set-ups
ExpressionLimit
2 set-ups
0 N/A
2 set-ups
Danfoss A/S © 10/2019 All rights reserved.
TRUE
0
TRUE
-
TRUE
-
TRUE
-
TRUE
0
TRUE
-
TRUE
-
FALSE
0
FALSE
0
FALSE
0
FALSE
0
TRUE
0
TRUE
-
TRUE
0
TRUE
-
TRUE
0
TRUE
0
TRUE
-
TRUE
-
FC 302
Change
Conver-
only
during
sion index
operation
TRUE
-
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
-
TRUE
0
TRUE
-
TRUE
-
TRUE
-
TRUE
0
Uint8
Uint8
Uint16
Uint16
Uint16
Uint8
Uint8
Uint16
Uint16
5
5
Uint16
Uint16
Uint8
Uint8
Uint16
Uint8
Uint16
Uint32
Uint16
Uint16
Type
Uint8
OctStr[4
]
OctStr[4
]
OctStr[4
]
OctStr[4
]
TimD
OctStr[4
]
VisStr[4
8]
VisStr[4
8]
VisStr[1
7]
Uint8
TimD
Uint8
Uint8
Uint8
OctStr[6
]
333

Advertisement

Table of Contents
loading