Danfoss VLT AutomationDrive FC 301 Programming Manual page 18

Hide thumbs Also See for VLT AutomationDrive FC 301:
Table of Contents

Advertisement

How to Program
Operating variable
Parameter 16-00 Control Word
2
2
Parameter 16-01 Reference [Unit]
Parameter 16-02 Reference [%]
Parameter 16-03 Status Word
Parameter 16-05 Main Actual Value [%]
Parameter 16-10 Power [kW]
Parameter 16-11 Power [hp]
Parameter 16-12 Motor Voltage
Parameter 16-13 Frequency
Parameter 16-14 Motor current
Parameter 16-16 Torque [Nm]
Parameter 16-17 Speed [RPM]
Parameter 16-18 Motor Thermal
Parameter 16-20 Motor Angle
Parameter 16-30 DC Link Voltage
Parameter 16-32 Brake Energy /s
Parameter 16-33 Brake Energy Average
Parameter 16-34 Heatsink Temp.
Parameter 16-35 Inverter Thermal
Parameter 16-36 Inv. Nom. Current
Parameter 16-37 Inv. Max. Current
Parameter 16-38 SL Controller State
Parameter 16-39 Control Card Temp.
Parameter 16-40 Logging Buffer Full
Parameter 16-50 External Reference
Parameter 16-51 Pulse Reference
Parameter 16-52 Feedback[Unit]
Parameter 16-53 Digi Pot Reference
Parameter 16-60 Digital Input
Parameter 16-61 Terminal 53 Switch Setting
Parameter 16-62 Analog Input 53
Parameter 16-63 Terminal 54 Switch Setting
Parameter 16-64 Analog Input 54
Parameter 16-65 Analog Output 42 [mA]
Parameter 16-66 Digital Output [bin]
Parameter 16-67 Pulse Input #29 [Hz]
Parameter 16-68 Freq. Input #33 [Hz]
Parameter 16-69 Pulse Output #27 [Hz]
Parameter 16-70 Pulse Output #29 [Hz]
Parameter 16-71 Relay Output [bin]
Parameter 16-72 Counter A
Parameter 16-73 Counter B
Parameter 16-80 Fieldbus CTW 1
Parameter 16-82 Fieldbus REF 1
Parameter 16-84 Comm. Option STW
Parameter 16-85 FC Port CTW 1
Parameter 16-86 FC Port REF 1
Parameter 16-90 Alarm Word
Parameter 16-92 Warning Word
Parameter 16-94 Ext. Status Word
Table 2.1 Units
16
®
VLT
AutomationDrive FC 301/302
Status view I
Unit
This readout state is standard after start-up or initialization.
hex
Press [Info] to obtain information about the units linked to
[Unit]
the shown operating variables (1.1, 1.2, 1.3, 2 and 3).
%
See the operating variables shown in Illustration 2.10.
hex
%
[kW]
[hp]
[V]
[Hz]
[A]
Nm
[RPM]
%
Illustration 2.10 Status View I
V
kW
Status view II
kW
See the operating variables (1.1, 1.2, 1.3, and 2) shown in
°C
Illustration 2.11.
%
In the example, speed, motor current, motor power, and
A
frequency are selected as variables in the 1
A
°C
[Unit]
bin
V
Illustration 2.11 Status View II
V
Status view III
[mA]
This state shows the event and action of the smart logic
[bin]
control. For further information, see
[Hz]
chapter 3.13 Parameters: 13-** Smart Logic Control.
[Hz]
[Hz]
[Hz]
hex
hex
Illustration 2.12 Status View III
hex
hex
hex
Danfoss A/S © 10/2019 All rights reserved.
Status
799 RPM
7.83 A
1.1
0.000
1.2
53.2 %
Auto Remote Ramping
2
3
1.3
Status
207RPM
5.25A
1.1
6.9
Hz
Auto Remote Running
Status
778 RPM
0.86 A
State: 0 o 0 (o )
When: -
Do: -
Auto Remote Running
1 (1)
36.4 kw
st
nd
and 2
lines.
1 (1)
24.4 kW
1.3
1.2
2
1 (1)
4.0 kW
M0013101