Parameter Descriptions
4.14 Parameters: 15-** Drive Information
4.14.1 15-0* Operating Data
15-00 Operating hours
Range:
0 h
[0 - 0x7fffffff. h] View how many hours the frequency
*
4
4
15-01 Running Hours
Range:
0 h
[0 -
*
0x7fffffff. h]
15-02 kWh Counter
Range:
0 kWh
[0 -
*
2147483647
kWh]
15-03 Power Up's
Range:
0
[0 - 2147483647 ] View the number of times the frequency
*
15-04 Over Temp's
Range:
0
[0 - 65535 ] View the number of frequency converter
*
15-05 Over Volt's
Range:
0
[0 - 65535 ] View the number of frequency converter
*
15-06 Reset kWh Counter
Option:
[0]
Do not reset
*
[1]
Reset counter Press [OK] to reset the kWh counter to 0
15-07 Reset Running Hours Counter
Option:
[0]
Do not reset
*
[1]
Reset counter Press [OK] to reset the running hours
100
VLT
Function:
converter has run. The value is saved,
when the frequency converter is turned
off.
Function:
View how many hours the frequency
converter has run. Reset the counter in
parameter 15-07 Reset Running Hours
Counter. The value is saved, when the
frequency converter is turned off.
Function:
Registers the power consumption of
the motor as an average value over 1
hour. Reset the counter in
parameter 15-06 Reset kWh Counter.
Function:
converter has been powered up.
Function:
temperature faults.
Function:
overvoltages.
Function:
No reset of the kWh counter is required.
(see parameter 15-02 kWh Counter).
Function:
counter to zero (see
parameter 15-01 Running Hours.
Danfoss A/S © 7/2015 All rights reserved.
®
AutomationDrive FC 360
4.14.2 15-3* Alarm Log
Parameters in this group are array parameters, where up to
10 fault logs can be viewed. 0 is the most recent logged
data, and 9 is the oldest. Fault codes, values, and time
stamp can be viewed for all logged data.
15-30 Alarm Log: Error Code
Range:
0
[0 - 255 ] View the error code and look up its meaning in
*
15-31 InternalFaultReason
Range:
0
[-32767 -
*
32767 ]
4.14.3 15-4* Drive Identification
Parameters containing read-only information about the
hardware and software configuration of the frequency
converter.
15-40 FC Type
Range:
0
[0 - 0 ] View the frequency converter type. The readout is
*
15-41 Power Section
Range:
0
[0 - 20 ] View the FC type. The readout is identical to the
*
15-42 Voltage
Range:
0
[0 - 20 ] View the FC type. The readout is identical to the
*
15-43 Software Version
Range:
0
[0 - 5 ] View the combined SW version (or package
*
15-44 Ordered Typecode String
Range:
0
[0 - 40 ] View the type code string used for reordering the
*
Function:
chapter 6 Troubleshooting.
Function:
View an extra description of the error. This
parameter is mostly used in combination
with Alarm 38 Internal Fault.
Function:
identical to the power field of the type code
definition, characters 1–6.
Function:
power field of the type code definition, characters
7–10.
Function:
power field type of the type code definition,
characters 11–12.
Function:
version) consisting of power SW and control SW.
Function:
frequency converter in its original configuration.
MG06C602