Parameter Descriptions
8-41 Parameters for Signals
Option:
Function:
[3664]
Terminal
X49/11 Bus
Control
[4029]
B-EMF
Protection Log
Readout
[4280]
Safe Option
Status
[4282]
Safe Control
Word
[4283]
Safe Status
Word
[4285]
Active Safe
Func.
[4287]
Time Until
Manual Test
8-42 PCD Write Configuration
Range:
Function:
Size
[0 - 9999 ]
Select the parameters to be
related
assigned to the PCD's telegrams.
*
The number of available PCDs
depends on the telegram type. The
values in the PCDs are then written
to the selected parameters as data
values.
8-43 PCD Read Configuration
Range:
Function:
Size
[0 - 9999 ]
Select the parameters to be
related
assigned to the PCDs of the
*
telegrams. The number of available
PCDs depends on the telegram
type. PCDs contain the actual data
values of the selected parameters.
When Block Transfer Mode (BTM) is enabled, all the
parameters are written into a temporary buffer in the
frequency converter via the Fieldbus. After writing all the
required parameters to the drive, when in BTM mode, a
Commit command is send to the frequency converter. The
frequency converter ensures correct adaptation of the
parameters.
8-45 BTM Transaction Command
Option:
Function:
NOTICE
This parameter cannot be
adjusted while the motor is
running. The block is only
applicable for software version
48.XX
[0]
Off
*
M0013101
Programming Guide
8-45 BTM Transaction Command
Option:
[1]
[2]
[3]
8-45 BTM Transaction Command
Option:
[0]
*
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
8-46 BTM Transaction Status
Option:
[0]
*
[1]
[2]
[3]
[4]
[5]
[6]
[7]
Danfoss A/S © 10/2019 All rights reserved.
Function:
Start
Transaction
Commit
Commit all parameters that have
transaction
been send during BTM mode.
Clear error
When chapter 3.9.5 8-46 BTM
Transaction Status shows an error
(3-8), the parameter must be
cleared by setting this value.
Function:
NOTICE
This parameter cannot be
adjusted while the motor is
running. The block is only
applicable for software version
8.XX.
Off
Write to Active
Setup
Commit
transaction
Clear error
Write to Setup
1
Write to Setup
2
Write to Setup
3
Write to Setup
4
Cancel BTM
Abort any BTM activity. Parameters
transaction
are not committed.
Function:
Off
Transaction
Started
Transaction
Comitting
Transaction
Timeout
Err. Non-
existing Par.
Err. Par. Out of
Range
Transaction
Failed
SO Config
Check
3
3
197