Parameter Descriptions
18-21 Master Position
Range:
0 Custom-
ReadoutUni
- 2147483647
t2
CustomRea-
*
3
3
doutUnit2]
18-23 Virtual Master Pos.
Range:
0 Custom-
ReadoutUni
- 2147483647
t2
CustomRea-
*
doutUnit2]
18-27 Safe Opt. Est. Speed
Range:
0 RPM
*
30000 RPM]
18-28 Safe Opt. Meas. Speed
Range:
0 RPM
*
30000 RPM]
18-29 Safe Opt. Speed Error
Range:
0 RPM
*
30000 RPM]
18-36 Analog Input X48/2 [mA]
Range:
0
*
270
Function:
[-2147483648
Shows the actual master position
based on the source selected in
parameter 3-16 Reference Resource 2.
Master position is converted to
follower position units by the
master scale set in
parameter 3-22 Master Scale
Numerator and
parameter 3-23 Master Scale
Denominator.
Function:
[-2147483648
Shows the current virtual master
position which is calculated by the
virtual master profile generator.
Virtual master position in position
units as defined in parameter group
17-0* Position Scaling. Virtual master
position is converted to follower
position units by the master scale
set in parameter 3-22 Master Scale
Numerator and
parameter 3-23 Master Scale
Denominator.
Function:
[-30000 -
Shows the speed that the
frequency converter estimates and
®
sends to VLT
Safety Option
MCB 15X.
Function:
[-30000 -
Shows the speed measured by VLT
Safety Option MCB 15X.
Function:
[-30000 -
Shows the difference between the
speed measured by VLT
Option MCB 15X and the speed
estimated by frequency converter.
Function:
[-20 - 20 ]
View the actual current measured
at input X48/2.
Danfoss A/S © 10/2019 All rights reserved.
®
VLT
AutomationDrive FC 301/302
18-37 Temp. Input X48/4
Range:
0
*
18-38 Temp. Input X48/7
Range:
0
*
18-39 Temp. Input X48/10
Range:
0
*
3.18.2 18-4* PGIO Data Readouts
Parameters for configuring the readout of VLT
Programmable I/O MCB 115.
18-40 Analog Input X49/1
Range:
0
*
18-41 Analog Input X49/3
Range:
0
*
18-43 Analog Out X49/7
®
Range:
0
*
®
Safety
18-44 Analog Out X49/9
Range:
0
*
Function:
[-500 - 500 ]
View the actual temperature
measured at input X48/4. The
temperature unit is based on the
selection in parameter 35-00 Term.
X48/4 Temperature Unit.
Function:
[-500 - 500 ]
View the actual temperature
measured at input X48/7. The
temperature unit is based on the
selection in parameter 35-02 Term.
X48/7 Temperature Unit.
Function:
[-500 - 500 ]
View the actual temperature
measured at input X48/10. The
temperature unit is based on the
selection in parameter 35-04 Term.
X48/10 Temperature Unit.
Function:
[-20 - 20 ]
Function:
[-20 - 20 ]
Function:
[0 - 30 ]
Shows the actual value at output of
terminal X49/7 in V or mA. The
value reflects the selection in
parameter 36-40 Terminal X49/7
Analogue Output.
Function:
[0 - 30 ]
Shows the actual value at output of
terminal X49/9 in V or mA. The
value reflects the selection in
parameter 36-50 Terminal X49/9
Analogue Output.
®
M0013101