Parameter Descriptions
42-48 S-ramp Ratio at Decel. Start
Range:
Function:
50 %
[1 - 99 %]
The proportion of the total ramp
*
down time (parameter 42-42 Delay
Time) where the deceleration
torque increases. The larger the
percentage value, the greater the
jerk compensation achieved, and
thus the lower the torque jerks in
the application.
42-49 S-ramp Ratio at Decel. End
Range:
Function:
50 %
[1 - 99 %]
The proportion of the total
*
rampdown time
(parameter 42-42 Delay Time) where
the deceleration torque decreases.
The larger the percentage value,
the greater the jerk compensation
achieved, and thus the lower the
torque jerks in the application.
42-50 Cut Off Speed
Range:
Function:
270 RPM
[120 - 10000
Speed at which the fail-safe
*
RPM]
reaction gets activated. This should
be the value of parameter 42-51
Speed Limit plus a tolerance.
42-51 Speed Limit
Range:
Function:
150 RPM
[0 - 9999
Maximum speed allowed when the
*
RPM]
SLS function is active.
42-52 Fail Safe Reaction
Option:
Function:
[0]
STO
STO is activated when the speed
*
exceeds the limit. This is applicable
only for SLS.
[1]
SS1-a
SS1-a is activated when the speed
exceeds the limit. This is applicable
only for SLS.
[2]
SS1-b
SS1-b is activated when the speed
exceeds the limit. This is applicable
only for SLS.
42-53 Start Ramp
Option:
Function:
[0]
No
If the speed at activation of SLS is
*
higher than the speed limit, it
activates a STO.
[1]
Yes
If the speed at activation of SLS is
higher than the speed limit, it
ramps down to the speed limit
M0013101
Programming Guide
3.30.2 42-54 Ramp Down Time
42-54 Ramp Down Time
Range:
1 s
*
42-60 Telegram Selection
Option:
[0]
*
[1]
42-61 Destination Address
Range:
1
*
42-70 Activation
Option:
[0]
*
[1]
42-71 Cut Off Speed
Range:
1500 RPM
42-80 Safe Option Status
Range:
0
*
42-81 Safe Option Status 2
Range:
0
*
42-82 Safe Control Word
Range:
0
*
42-83 Safe Status Word
Range:
0
*
42-85 Active Safe Func.
Option:
[0]
[1]
[2]
Danfoss A/S © 10/2019 All rights reserved.
Function:
[0.1 - 3600 s] Ramp-down time for start ramp.
Function:
None
PROFIsafe
Std.Tel.30
Function:
[1 - 65535 ]
Function:
Inactive
Deactivate Safe Maximum Speed
(SMS)
Active
Activate Safe Maximum Speed
(SMS).
Function:
[120 - 20000
Maximum allowed speed.
*
RPM]
Function:
[0 -
Shows the safety option status
4294967295 ]
word as a hexadecimal value.
Function:
[0 -
Shows the safety option status 2 as
2147483647 ]
a hexadecimal value. For example, it
contains DI1, DI2, and blank initial
state status.
Function:
[0 -
4294967295 ]
Function:
[0 -
4294967295 ]
Function:
STO
SS1-a
SS1-b
3
3
309