Danfoss VLT AutomationDrive FC 301 Programming Manual page 251

Hide thumbs Also See for VLT AutomationDrive FC 301:
Table of Contents

Advertisement

Parameter Descriptions
15-59 Filename
Range:
Function:
Size
[0 - 16 ]
Shows the currently used customer-
related
specific initial values (CSIV)
*
filename.
3.15.10 15-6* Option Ident.
This read-only parameter group contains information about
the hardware and software configuration of the options
installed in slots A, B, C0, and C1.
15-60 Option Mounted
Array [8]
Range:
Function:
0
[0 - 30 ]
Shows the type of the installed
*
option.
15-61 Option SW Version
Array [8]
Range:
Function:
0
[0 - 20 ]
View the installed option software
*
version.
15-62 Option Ordering No
Array [8]
Range:
Function:
0
[0 - 8 ]
Shows the ordering number for the
*
installed options.
15-63 Option Serial No
Array [8]
Range:
Function:
0
[0 - 18 ]
View the installed option serial
*
number.
15-70 Option in Slot A
Range:
Function:
0
[0 - 30 ]
View the type code string for the
*
option installed in slot A and a
translation of the type code string.
For example, for type code string
AX, the translation is No option.
15-71 Slot A Option SW Version
Range:
Function:
0
[0 - 20 ]
View the software version for the
*
option installed in slot A.
15-72 Option in Slot B
Range:
Function:
0
[0 - 30 ]
View the type code string for the
*
option installed in slot B and a
M0013101
Programming Guide
15-72 Option in Slot B
Range:
15-73 Slot B Option SW Version
Range:
0
*
15-74 Option in Slot C0/E0
Range:
0
*
15-75 Slot C0/E0 Option SW Version
Range:
0
*
15-76 Option in Slot C1/E1
Range:
0
*
15-77 Slot C1/E1 Option SW Version
Range:
0
*
15-80 Fan Running Hours
Range:
0 h
*
15-81 Preset Fan Running Hours
Range:
0 h
*
Danfoss A/S © 10/2019 All rights reserved.
Function:
translation of the type code string.
For example, for type code string
BX, the translation is No option.
Function:
[0 - 20 ]
View the software version for the
option installed in slot B.
Function:
[0 - 30 ]
View the type code string for the
option installed in slot C and a
translation of the type code string.
For example, for type code string
CXXXX, the translation is No option.
Function:
[0 - 20 ]
View the software version for the
option installed in slot C.
Function:
[0 - 30 ]
Shows the type code string for the
option in slot C1 (CXXXX if no
option) and the translation, that is
No option.
Function:
[0 - 20 ]
Shows the software version for the
installed option in option slot C.
Function:
[0 -
View how many hours the heat sink
2147483647 h]
fan has run (increments for every
hour). The value is saved when the
frequency converter is turned off.
Function:
[0 - 99999 h] Enter the preset fan running hours
counter, see parameter 15-80 Fan
Running Hours.
This parameter cannot be selected
via the serial port, RS485.
3
3
249

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vlt automationdrive fc 302

Table of Contents