Parameter Lists
5.2.3 2-** Brakes
Par.
Parameter description
No. #
2-0* DC-Brake
2-00
DC Hold Current
2-01
DC Brake Current
2-02
DC Braking Time
2-03
DC Brake Cut In Speed [RPM]
2-04
DC Brake Cut In Speed [Hz]
5
5
2-05
Maximum Reference
2-06
Parking Current
2-07
Parking Time
2-1* Brake Energy Funct.
2-10
Brake Function
2-11
Brake Resistor (ohm)
2-12
Brake Power Limit (kW)
2-13
Brake Power Monitoring
2-15
Brake Check
2-16
AC brake Max. Current
2-17
Over-voltage Control
2-18
Brake Check Condition
2-19
Over-voltage Gain
2-2* Mechanical Brake
2-20
Release Brake Current
2-21
Activate Brake Speed [RPM]
2-22
Activate Brake Speed [Hz]
2-23
Activate Brake Delay
2-24
Stop Delay
2-25
Brake Release Time
2-26
Torque Ref
2-27
Torque Ramp Up Time
2-28
Gain Boost Factor
2-29
Torque Ramp Down Time
2-3* Adv. Mech Brake
2-30
Position P Start Proportional Gain
2-31
Speed PID Start Proportional Gain
2-32
Speed PID Start Integral Time
2-33
Speed PID Start Lowpass Filter Time
2-34
Zero Speed Position P Proportional Gain
5.2.4 3-** Reference / Ramps
Par.
Parameter description
No. #
3-0* Reference Limits
3-00
Reference Range
3-01
Reference/Feedback Unit
3-02
Minimum Reference
3-03
Maximum Reference
3-04
Reference Function
3-05
On Reference Window
3-06
Minimum Position
324
®
VLT
AutomationDrive FC 301/302
Default value
50 %
50 %
10 s
ExpressionLimit
ExpressionLimit
MaxReference (P303)
50 %
3 s
ExpressionLimit
ExpressionLimit
ExpressionLimit
[0] Off
[0] Off
100 %
[0] Disabled
[0] At Power Up
100 %
ImaxVLT (P1637)
ExpressionLimit
ExpressionLimit
0 s
0 s
0.20 s
0 %
0.2 s
1 N/A
0 s
0.0500 N/A
0.0500 N/A
20.0 ms
2.0 ms
0.0000 N/A
Default value
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
[0] Sum
ExpressionLimit
-100000 CustomRea-
doutUnit2
Danfoss A/S © 10/2019 All rights reserved.
4-set-up
FC 302
Change
only
during
operation
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
4-set-up
FC 302
Change
only
during
operation
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
Conver-
Type
sion index
0
Uint8
0
Uint16
-1
Uint16
67
Uint16
-1
Uint16
-3
Int32
0
Uint16
-1
Uint16
-
Uint8
0
Uint16
0
Uint32
-
Uint8
-
Uint8
-1
Uint32
-
Uint8
-
Uint8
0
Uint16
-2
Uint32
67
Uint16
-1
Uint16
-1
Uint8
-1
Uint8
-2
Uint16
-2
Int16
-1
Uint8
-2
Uint16
-1
Uint8
-4
Uint32
-4
Uint32
-4
Uint32
-4
Uint16
-4
Uint32
Conver-
Type
sion index
-
Uint8
-
Uint8
-3
Int32
-3
Int32
-
Uint8
-3
Int32
0
Int32
M0013101