Parameter Descriptions
13-44 Logic Rule Boolean 3
Array [6]
Option:
Function:
alarm 166, ATEX ETR freq.lim.alarm is
active, the output is 1.
[92]
ATEX ETR freq.
Available if parameter 1-90 Motor
warning
Thermal Protection is set to [20]
ATEX ETR or [21] Advanced ETR. If
alarm 163, ATEX ETR cur.lim.warning
is active, the output is 1.
[93]
ATEX ETR freq.
Available if parameter 1-90 Motor
alarm
Thermal Protection is set to [20]
ATEX ETR or [21] Advanced ETR]. If
warning 165, ATEX ETR
freq.lim.warning is active, the output
is 1.
[94]
RS Flipflop 0
See parameter group 13-1*
Comparators.
[95]
RS Flipflop 1
See parameter group 13-1*
Comparators.
[96]
RS Flipflop 2
See parameter group 13-1*
Comparators.
[97]
RS Flipflop 3
See parameter group 13-1*
Comparators.
[98]
RS Flipflop 4
See parameter group 13-1*
Comparators.
[99]
RS Flipflop 5
See parameter group 13-1*
Comparators.
[100]
RS Flipflop 6
See parameter group 13-1*
Comparators.
[101]
RS Flipflop 7
See parameter group 13-1*
Comparators.
[102]
Relay 1
[103]
Relay 2
[104]
Relay 3
X47/VLT
113.
[105]
Relay 4
X47/VLT
113.
[106]
Relay 5
X47/VLT
113.
[107]
Relay 6
X47/VLT
113.
[108]
Relay 7
X34/VLT
[109]
Relay 8
X34/VLT
[110]
Relay 9
X34/VLT
M0013101
Programming Guide
®
Extended Relay Card MCB
®
Extended Relay Card MCB
®
Extended Relay Card MCB
®
Extended Relay Card MCB
®
Relay Card MCB 105.
®
Relay Card MCB 105.
®
Relay Card MCB 105.
Danfoss A/S © 10/2019 All rights reserved.
13-44 Logic Rule Boolean 3
Array [6]
Option:
Function:
NOTICE
[222]
Homing Ok
This option is available only
with software version 48.20
and newer.
Homing is completed with the
selected homing function
(parameter 17-80 Homing Function).
NOTICE
[223]
On Target
This option is available only
with software version 48.20
and newer.
Positioning is completed and the
on-target signal is sent when the
actual position is within
parameter 3-05 On Reference
Window for the duration of
parameter 3-09 On Target Time and
the actual speed does not exceed
parameter 3-05 On Reference
Window.
NOTICE
[224]
Position Error
This option is available only
with software version 48.20
and newer.
The position error exceeds the
value in parameter 4-71 Maximum
Position Error for the time set in
parameter 4-72 Position Error
Timeout.
NOTICE
[225]
Position Limit
This option is available only
with software version 48.20
and newer.
The position is outside the limits
set in parameter 3-06 Minimum
Position and
parameter 3-07 Maximum Position.
NOTICE
[226]
Touch on
Target
This option is available only
with software version 48.20
and newer.
Target position is reached in touch
probe position mode.
3
3
221