Danfoss VLT AutomationDrive FC 301 Programming Manual page 331

Hide thumbs Also See for VLT AutomationDrive FC 301:
Table of Contents

Advertisement

Parameter Lists
6-20
Terminal 54 Low Voltage
6-21
Terminal 54 High Voltage
6-22
Terminal 54 Low Current
6-23
Terminal 54 High Current
6-24
Terminal 54 Low Ref./Feedb. Value
6-25
Terminal 54 High Ref./Feedb. Value
6-26
Terminal 54 Filter Time Constant
6-3* Analog Input 3
6-30
Terminal X30/11 Low Voltage
6-31
Terminal X30/11 High Voltage
6-34
Term. X30/11 Low Ref./Feedb. Value
6-35
Term. X30/11 High Ref./Feedb. Value
6-36
Term. X30/11 Filter Time Constant
6-4* Analog Input 4
6-40
Terminal X30/12 Low Voltage
6-41
Terminal X30/12 High Voltage
6-44
Term. X30/12 Low Ref./Feedb. Value
6-45
Term. X30/12 High Ref./Feedb. Value
6-46
Term. X30/12 Filter Time Constant
6-5* Analog Output 1
6-50
Terminal 42 Output
6-51
Terminal 42 Output Min Scale
6-52
Terminal 42 Output Max Scale
6-53
Term 42 Output Bus Ctrl
6-54
Terminal 42 Output Timeout Preset
6-55
Analog Output Filter
6-6* Analog Output 2
6-60
Terminal X30/8 Output
6-61
Terminal X30/8 Min. Scale
6-62
Terminal X30/8 Max. Scale
6-63
Terminal X30/8 Bus Control
6-64
Terminal X30/8 Output Timeout Preset
6-7* Analog Output 3
6-70
Terminal X45/1 Output
6-71
Terminal X45/1 Min. Scale
6-72
Terminal X45/1 Max. Scale
6-73
Terminal X45/1 Bus Control
6-74
Terminal X45/1 Output Timeout Preset
6-8* Analog Output 4
6-80
Terminal X45/3 Output
6-81
Terminal X45/3 Min. Scale
6-82
Terminal X45/3 Max. Scale
6-83
Terminal X45/3 Bus Control
6-84
Terminal X45/3 Output Timeout Preset
5.2.8 7-** Controllers
Par.
Parameter description
No. #
7-0* Speed PID Ctrl.
7-00
Speed PID Feedback Source
7-01
Speed PID Droop
7-02
Speed PID Proportional Gain
7-03
Speed PID Integral Time
7-04
Speed PID Differentiation Time
M0013101
Programming Guide
ExpressionLimit
All set-ups
10 V
All set-ups
ExpressionLimit
All set-ups
20 mA
All set-ups
0 ReferenceFeedbackUnit
All set-ups
ExpressionLimit
All set-ups
0.001 s
All set-ups
0.07 V
All set-ups
10 V
All set-ups
0 ReferenceFeedbackUnit
All set-ups
ExpressionLimit
All set-ups
0.001 s
All set-ups
0.07 V
All set-ups
10 V
All set-ups
0 ReferenceFeedbackUnit
All set-ups
ExpressionLimit
All set-ups
0.001 s
All set-ups
ExpressionLimit
All set-ups
0 %
All set-ups
100 %
All set-ups
0 %
All set-ups
0 %
1 set-up
[0] Off
1 set-up
ExpressionLimit
All set-ups
0 %
All set-ups
100 %
All set-ups
0 %
All set-ups
0 %
1 set-up
ExpressionLimit
All set-ups
0 %
All set-ups
100 %
All set-ups
0 %
All set-ups
0 %
1 set-up
ExpressionLimit
All set-ups
0 %
All set-ups
100 %
All set-ups
0 %
All set-ups
0 %
1 set-up
Default value
4-set-up
ExpressionLimit
All set-ups
0 RPM
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
Danfoss A/S © 10/2019 All rights reserved.
TRUE
-2
TRUE
-2
TRUE
-5
TRUE
-5
TRUE
-3
TRUE
-3
TRUE
-3
TRUE
-2
TRUE
-2
TRUE
-3
TRUE
-3
TRUE
-3
TRUE
-2
TRUE
-2
TRUE
-3
TRUE
-3
TRUE
-3
TRUE
-
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-
TRUE
-
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-2
FC 302
Change
Conver-
only
during
sion index
operation
FALSE
-
TRUE
67
TRUE
-3
TRUE
-4
TRUE
-4
Int16
Int16
Int16
Int16
Int32
Int32
Uint16
Int16
Int16
Int32
Int32
5
5
Uint16
Int16
Int16
Int32
Int32
Uint16
Uint8
Int16
Int16
N2
Uint16
Uint8
Uint8
Int16
Int16
N2
Uint16
Uint8
Int16
Int16
N2
Uint16
Uint8
Int16
Int16
N2
Uint16
Type
Uint8
Uint16
Uint16
Uint32
Uint16
329

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vlt automationdrive fc 302

Table of Contents