M800V/M80V Series PLC Development Manual
5 Peripheral Development Environment (GX Works2)
5.2 Types of GX Works2 Projects and Programs Used for Mitsubishi Electric CNC
5.2 Types of GX Works2 Projects and Programs Used for Mitsubishi
Electric CNC
This chapter describes the types of GX Works2 projects and programs that can be used in developing ladders for CNC
controllers.
5.2.1 Support Status of Project Types, Program Types and POUs
The following lists show the project types that can be used in developing ladders for CNC controllers, and the program types
and POUs (Program Organization Units) that can be handled in each project type.
The program types marked by ◎ can be used in developing ladders for this CNC.
The program types marked by × cannot be used in developing ladders for this CNC.
The difference between machine sequence and user safety sequence is as follows.
Machine sequence: Control ladder to control machine tools
User safety sequence: Control ladder for safety-related I/O observation created by the Smart Safety observation function
[List of project types]
◎ : Supported; × : Not supported
Program type
Simple project (without labels)
Simple project (with labels)
Structured project
Note
(1) By selecting [Project] - [Change Project Type], simple projects (without labels) can be changed to simple projects (with
labels), and simple projects (with labels) to structured projects after they are created. Note that these changes cannot be
reverted.
[List of program types for simple projects (without labels)]
◎ : Supported; × : Not supported
Program type
Ladder (without labels)
List
ST
SFC
[List of POUs for simple projects (without labels)]
◎ : Supported; × : Not supported
Program type
FB
Structure
Function
IB-1501614-B
Machine se-
User safety
Support in GX
quence
sequence
Developer
◎
◎
◎
◎
◎
◎
Machine se-
User safety
Support in GX
quence
sequence
Developer
◎
◎
×
×
×
×
×
×
Machine se-
User safety
Support in GX
quence
sequence
Developer
×
×
×
×
×
×
58
Remarks
◎
The label function can only be monitored in PLC
×
on-board
Structured projects can only be monitored in PLC
×
on-board
Remarks
◎
Editing list for each ladder block is possible
◎
×
×
Remarks
×
×
×