Digital Keypad - Delta C2000 Series User Manual

Classical field oriented control ac motor drive
Hide thumbs Also See for C2000 Series:
Table of Contents

Advertisement

Chapter 7 Optional Accessories

7-7 Digital Keypad

7-7-1 KPC-CE01
Key
ESC
ESC Key
Press ESC key to return to the previous page. It also functions as a return to last category key in the sub-menu.
MENU
Menu Key
Press MENU key under any condition will return to the main MENU.
Menu content:
1. Parameter Detail
2. Copy Parameter
ENTER
ENTER Key
Press ENTER and go to the next level. If it is the last level then press ENTER to execute the command.
HAND
HAND ON Key
1. HAND key will operates according to the parameter settings when the source of HAND master frequency
command and the source of HAND operation command is properly set,. The factory setting of the source
command for frequency and operation are from the digital keypad .
2. Press HAND key in stop status, the drive setting switches to the parameter setting of HAND. Press HAND
key in during operation, the drive will come to stop then switches to the parameter setting of HAND.
3. When process complete: H/A LED ON.
AUTO
Auto Operation Key
1. AUTO function executes according to the parameter settings of the source of AUTO frequency and AUTO
operation. The factory setting is the external terminal (source of operation is 4-20mA).
2. Press the ATUO key in stop status, the drivel switches to auto-setting. Press the auto key during operation
status, the drivel will come to stop and switch to auto-setting.
3. When process complete: H/A LED is OFF
FWD/REV
Operation Direction Key
1. FWD/REV key controls the operation direction but will NOT activate the drive. FWD: forward, REV: reverse.
2. The drive operates in the direction as shown by the LED light.
RUN
Start Key
1. This button is functional only when the keypad is the source of the command.
2. This button allows the motor drive to run by following its settings. See Description of LED functions for LED
status
3. Press repeatedly the "RUN" button is allow while the motor drive is stopping.
STOP
Stop Key.
1. STOP key has the highest priority in command.
2. Press STOP key, the drive will come to stop under any condition.
3. The RESET key can be used to reset the drive when faults occur. If the RESET key is not responding, check
MENU
C2000 Series
A
: LED Disp lay
D ispla y freq uen cy, cu rre nt, vo ltag e and erro r etc.
: Status Indi cator
F: Fre que ncy C omma nd
H: Outp ut Frequ ency
U: User De fine d Uni ts
ERR: CAN Erro r Ind icator
RU N: CAN Ru n Indi ca tor
C
: Function
(Re fer to the chart foll ow s for deta il de scripti on )
3. Keypad locked
4. PLC Function
Fault Records and check the most recent fault.
Description
7-16

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents