Chapter 12 Description of Parameter Settings C2000 Series
When dEb arises at Master, MO will send a dEb signal to Slave. Then
Slave will follow Master's command and decelerate to stop
simultaneously.
When drive stops, the corresponding multi-function terminal will
be ON if the frequency is less than Pr.02-34. After it is ON, it will
be OFF when brake delay time exceeds Pr.02-32.
Output Frequency
RUN
Multi-function
Output
MO=d47
Control multi-function output terminals through CANopen.
If to control RY2, then the Pr02-14 = 50.
The mapping table of the CANopen DO is below:
Setting of
physical
related
terminal
parameters
RY1
P2-13 = 50
RY2
P2-14 = 50
MO1
P2-16 = 50
MO2
P2-17 = 50
MO10
P2-36 = 50
RY10
MO11
P2-37 = 50
RY11
RY12
P2-38 = 50
RY13
P2-39 = 50
RY14
P2-40 = 50
RY15
P2-41= 50
Refer to Chapter 15-3-5 for more information.
12-02-17
Descriptions
Output Frequency
< Pr.02-34
RUN
Attribute
Corresponding Index
RW
The bit 0 at 2026-41
RW
The bit 1 at 2026-41
RW
The bit 2 at 2026-41
RW
The bit 3 at 2026-41
The bit 4 at 2026-41
RW
The bit 5 at 2026-41
The bit 6 at 2026-41
RW
The bit 7 at 2026-41
RW
The bit 8 at 2026-41
RW
The bit 9 at 2026-41
RW
The bit 10 at 2026-41
RW
The bit 0 at 2026-41
Time
02-32