Advertisement

Chapter 11 Summary of Parameter Settings C2000 Series
Pr.
Explanation
06-23
Fault Output Option 1
06-24
Fault Output Option 2
06-25
Fault Output Option 3
06-26
Fault Output Option 4
Electronic Thermal Relay
06-27
Selection 2 (Motor 2)
Electronic Thermal
06-28
Characteristic for Motor 2
06-29
PTC Detection Selection
Settings
56: Communication error (CE3)
57: Communication error (CE4)
58: Communication Time-out (CE10)
59: PU Time-out (CP10)
60: Brake transistor error (bF)
61: Y- connection/ -connection switch error (ydc)
62: Decel. Energy Backup Error (dEb)
63: Slip error (oSL)
64: Electromagnet switch error (ryF)
65: PG Card Error (PGF5)
66-67: Reserved
68: Sensorless estimated speed have wrong direction
69: Sensorless estimated speed is over speed
70: Sensorless estimated speed deviated
71: Reserved
72: STO Loss 1
73: External safety gate S1
74~75: Reserved
76: STO
77: STO Loss 2
78: STO Loss 3
79: U phase over current (Uocc)
80: V phase over current (Vocc)
81: W phase over current (Wocc)
82: U phase output phase loss (OPHL)
83: V phase output phase loss (OPHL)
84: W phase output phase loss (OPHL)
85: PG-02U ABZ hardware disconnection
86: PG-02U UVW hardware disconnection
87~88: Reserved
89: Initial rotor position detection error
90: Inner PLC function is forced to stop
91~100: Reserved
101: CANopen software disconnect1 (CGdE)
102: CAN open software disconnect2 (CHbE)
103: CANopen synchronous error (CSYE)
104: CANopen hardware disconnect (CbFE)
index setting error
105: CANopen
slave station number setting error
106: CANopen
(CAdE)
index setting exceed limit
107: CANopen
108~110: Reserved
111: Internal communication overtime error(InrCOM)
112: PM sensorless shaft Lock error
113: Software OC
0~65535(refer to bit table for fault code)
0~65535(refer to bit table for fault code)
0~65535(refer to bit table for fault code)
0~65535(refer to bit table for fault code)
0: Special motor (with external forced cooling)
1: Self-cooled motor (so motor with fan on the shaft)
2: Disable
30.0~600.0 sec
0: Warn and keep operation
1: Warn and ramp to stop
2: Warn and coast to stop
11-24
Factory
Setting
(CIdE)
(CFrE)
60.0
0
0
0
0
2
0