Once output frequency reaches desired frequency and the corresponding multi-function output
terminal is set to 3 or 4 (Pr.02-13, 02-14, 02-36, and 02-37), this multi-function output terminal will be
ON.
Fcmd=60Hz
02-24=40Hz
02-25=2Hz
02-22=10Hz
02-23=2Hz
02-13,02-14,
02-36,02-37,
02-13,02-14,
02-36,02-37, =4
Brake Delay Time
Settings 0.000~65.000 sec
When the AC motor drive runs after Pr.02-32 delay time, the corresponding multi-function output
terminal (12: mechanical brake release) will be ON. It has to use this function with DC brake.
Chapter 12 Description of Parameter Settings C2000 Series
H
=3
12-02-21
42Hz
40Hz
38Hz
12Hz
10Hz
8Hz
T
Factory Setting: 0.000