8: Display estimate output torque % (t = 00: positive torque; -00 negative
torque) (t) (Unit: %)
9: Display PG feedback (G) (refer to Note 1) (Unit: PLS)
10: Display PID feedback (b) (Unit: %)
11: Display AVI in % (1.), 0~10V/4-20mA/0-20mA corresponds to 0~100%
(Refer to Note 2) (Unit: %)
12: Display ACI in % (2.),
0~100% Refer to Note 2 (Unit: %)
13: Display AUI in % (3.), -10V~10V corresponds to -100~100%(Refer to
Note 2) (Unit: %)
14: Display the temperature of IGBT (i.) (Unit:
15: Display the temperature of capacitance (c.) (Unit:
16: The status of digital input (ON/OFF) refer to Pr.02-12 (i) (Refer to
Note3)
17: Display digital output status ON/OFF (Pr.02-18) (o) (refer to NOTE 4)
18: Display the multi-step speed that is executing (S)
19: The corresponding CPU pin status of digital input (d) (refer to NOTE 3)
20: The corresponding CPU pin status of digital output (0.) (refer to NOTE
4)
21: Actual motor position (PG1 of PG card). When the motor direction
changes or the drive stops, the counter will start from 0 (display value
restarts counting from 0) (Max. 65535) (P.)
22: Pulse input frequency (PG2 of PG card) (S.)
23: Pulse input position (PG2 of PG card) (max. 65535) (q.)
24: Position command tracing error (E.)
25: Overload counting (0.00~100.00%) (o.) (Refer to Note 6) (Unit: %)
26: GFF Ground Fault (G.) (Unit: %)
27: DC Bus voltage ripple (r.) (Unit: %)
28: Display PLC register D1043 data (C) display in hexadecimal
29: Display PM motor pole section (EMC-PG01U application) (4.)
30 : Display output of user defined (U)
31 : H page x 00-05 Display user Gain(K)
32: Number of actual motor revolution during operation (PG card plug in
and Z phase signal input) (Z.)
33: Motor actual position during operation (when PG card is connected)(q)
34: Operation speed of fan (F.) (Unit: %)
35: Control Mode display: 0= Speed control mode (SPD), 1= torque control
mode (TQR) (t.)
36: Present operating carrier frequency of drive (Hz) (J.)
37: Reserved
38: Display drive status (6.) (Refer to Note 7)
40:
Torque command (L.) (Unit: %)
Chapter 12 Description of Parameter Settings C2000 Series
4~20mA/0~10V/0-20mA corresponds to
12-00-3
)
)