Status monitor read
only
Chapter 12 Description of Parameter Settings C2000 Series
Register
1110B: 14th
1111B: 15th
Bit12
1: Enable bit06-11 function
Bit14~13 00B No function
01B Operated by digital keypad
10B Operated by Pr.00-21 setting
11B Change operation source
Bit15
Reserved
2001H Frequency command(XXX.XXHz)
2002H
Bit0
1 EF (external fault) on
1 Reset
Bit1
1 B.B ON
Bit2
Bit15~3 Reserved
High byte: Warn Code
2100H
Low Byte: Error Code
2101H
Bit1~0
AC Drive Operation Status
00B: Drive stops
01B: Drive decelerating
10B: Drive standby
11B: Drive operating
Bit2
1 JOG Command
Bit4~3
Operation Direction
00B: FWD run
01B: From REV run to FWD run
10B: REV run
11B: From FWD run to REV run
Bit8
1 Master frequency controlled by communication
interface
Bit9
1 Master frequency controlled by analog signal
Bit10
1 Operation command controlled by
communication interface
Bit11
1 Parameter locked
Bit12
1 Enable to copy parameters from keypad
Bit15~13 Reserved
2102H Frequency command
2103H Output frequency
2104H Output current XX.XXA . When current is higher than
655.35,it will shift decimal as XXX.XA . The decimal can refer
to High byte of 211F.
2105H DC-BUS Voltage
2106H Output voltage XXX.XV
2107H Current step number of Multi-Step Speed Operation
2108H Reserved
2109H Counter value
210AH Power Factor Angle (XXX.X)
210BH Output Torque
210CH Actual motor speed XXXXXrpm)
210DH Number of PG feed back pulses 0~65535
210EH Number of PG2 pulse commands 0~65535
210FH Power output
2116H Multi-function display (Pr.00-04)
12-09-9
Function
Step Speed Frequency
Step Speed Frequency
XXX.XX Hz
XXX.XX Hz
XXX.XV
XXX.X%
X.XXX KWH