Delta C2000 Series User Manual page 72

Classical field oriented control ac motor drive
Hide thumbs Also See for C2000 Series:
Table of Contents

Advertisement

Chapter 6 Control Terminals C2000 Series
Terminals
Multi-function Output 2
MO2
(photocoupler)
MCM
Multi-function Output Common
Multi-function relay output 1 (N.O.)
RA1
a
Multi-function relay output 1 (N.C.)
RB1
b
RC1
Multi-function relay common
RA2
Multi-function relay output 2 (N.O.) a
Multi-function relay output 2 (N.C.) b
RB2
RC2
Multi-function relay common
Potentiometer power supply
+10V
Potentiometer power supply
-10V
Analog voltage input
AVI
Analog current input
ACI
Auxiliary analog voltage input
AUI
Terminal Function
+10V
AUI
( -10V~+ 10V)
A CM
-1 0V
inter nal c irc ui t
Factory Setting (NPN mode)
Max 48Vdc 50mA
Resistive Load:
3A(N.O.)/3A(N.C.) 250VAC
5A(N.O.)/3A(N.C.) 30VDC
Inductive Load (COS 0.4):
1.2A(N.O.)/1.2A(N.C.) 250VAC
2.0A(N.O.)/1.2A(N.C.) 30VDC
It is used to output each monitor signal, such as drive is in
operation, frequency attained or overload indication.
Analog frequency setting: +10Vdc 20mA
Analog frequency setting: -10Vdc 20mA
Impedance: 20k
Range: 0~20mA/4~20mA/0~10V =0~Max. Output Frequency
(Pr.01-00)
AVI switch, factory setting is 0~10V
Impedance: 250
Range: 0~20mA/4~20mA/0~10V = 0 ~ Max. Output
Frequency (Pr.01-00)
ACI Switch, factory setting is 4~20mA
Impedance: 20k
Range: -10~+10VDC=0 ~ Max. Output Frequency(Pr.01-00)
6-4
MO1
MO2
MCM

Hide quick links:

Advertisement

Table of Contents
loading