Chapter 12 Description of Parameter Settings C2000 Series
Bit0
Bit1
Bit2
Bit3
Bit4
Bit5
Bit6
Fault Code
current
Volt.
OL
SYS
FBK
EXI
CE
60: Brake transistor error (bF)
61: Y-connection/ -connection switch error
(ydc)
62: Decel. Energy Backup Error (dEb)
63: Slip error (oSL)
64: Electromagnet switch error (ryF)
65 : PG Card Error (PGF5)
66~67: Reserved
68: Sensorless estimated speed have wrong
direction
69: Sensorless estimated speed is over speed
70: Sensorless estimated speed deviated
71: Reserved
72: STO Loss 1
73: External safety gate S1
74~75: Reserved
76: STO
77: STO Loss 2
78: STO Loss 3
79: U phase over current (Uocc)
80: V phase over current (Vocc)
81: W phase over current (Wocc)
82: OPHL U phase output phase loss
83: OPHL Vphase output phase loss
84: OPHL Wphase output phase loss
85: PG-02U ABZ hardware disconnection
86: PG-02U UVW hardware disconnection
87~88: Reserved
89: Initial rotor position detection error
90: Inner PLC function is forced to stop
91~100: Reserved
101: CGdE CANopen software disconnect1
102: CHbE CANopen software disconnect2
103: CSYE CANopen synchronous error
104: CbFE CANopen hardware disconnect
105: CIdE CANopen index setting error
106: CAdE CANopen slave station number
setting error
107: CFrE CANopen index setting exceed limit
12-06-13