Function Key
1.
2.
3.
HAND ON Key
1.
2.
3.
1.
2.
3.
Descriptions of LED Functions
LED
Steady ON: operation indicator of the AC motor drive, including DC brake, zero speed,
Blinking: drive is decelerating to stop or in the status of base block.
Steady OFF: drive doesn't execute the operation command
Steady ON: stop indicator of the AC motor drive.
Blinking: drive is in the standby status.
Steady OFF: drive doesn't execute "STOP" command.
Operation Direction LED
1. Green light is on, the drive is running forward.
2. Red light is on, the drive is running backward.
3. Twinkling light: the drive is changing direction.
(Only KPC-CE01 support this function)
Setting can be done during operation.
HAND LED: When HAND LED is on (HAND mode); when HAND LED is off (AUTO mode).
(Only KPC-CE01Support this function )
Setting can be done during operation.
AUTO LED: when AUTO LED is on (AUTO mode); when AUTO LED is off (HAND mode).
The functions keys have factory settings and can be defined by users. The factory settings
of F1 and F4 work with the function list below. For example, F1 is JOG function, F4 is a
speed setting key for adding/deleting user defined parameters.
Other functions must be defined by TPEditor first. TPEditor software V1.30.6 is available
for download at:
http://www.delta.com.tw/ch/product/em/download/download_main.asp?act=3&pid=1&cid=
1&tpid=3
Installation Instruction for TPEditor is on page 10-15 of this chapter.
This key is executed by the parameter settings of the source of Hand frequency and hand
operation. The factory settings of both source of Hand frequency and hand operation are
the digital keypad.
Press HAND ON key at stop status, the setting will switch to hand frequency source and
hand operation source. Press HAND ON key at operation status, it stops the AC motor
drive first (display AHSP warning), and switch to hand frequency source and hand
operation source.
Successful mode switching for KPC-CE01, "H/A" LED will be on; for KPC-CC01, it will
display HAND mode/ AUTO mode on the screen.
This key is executed by the parameter settings of the source of AUTO frequency and
AUTO operation. The factory setting is the external terminal (source of operation is
4-20mA).
Press Auto key at stop status, the setting will switch to hand frequency source and hand
operation source. Press Auto key at operation status, it stops the AC motor drive first
(display AHSP warning), and switch to auto frequency source and auto operation source.
Successful mode switching for KPC-CE01, "H/A" LED will be off; for KPC-CC01, it will
display HAND mode/ AUTO mode on the screen
standby, restart after fault and speed search.
Chapter 10 Digital Keypad
Descriptions
10-3
C2000

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents