Delta C2000 Series User Manual page 562

Classical field oriented control ac motor drive
Hide thumbs Also See for C2000 Series:
Table of Contents

Advertisement

API
ECMP
110
D
P
Bit device
X
Y
M
K
S1
S2
D
Notes on operand usage:
The operand D occupies three consecutive points
Please refer to the function specifications table for each device in
series for the scope of device usage
S
: Comparison of binary floating point numbers value 1. S
1
binary floating point numbers value 2. D: Results of comparison, occupies 3
consecutive points.
When binary floating point number 1 is compared with comparative binary
floating point number 2, the result of comparison (>, =, <) will be expressed in D.
If the source operand S
transform the constant to a binary floating-point number for the purpose of
comparison.
When the designated device is M10, it will automatically occupy M10-M12.
When X0=On, the DECMP command executes, and one of M10-M12 will be On.
When X0=Off, the DECMP command will not execute, and M10-M12 will remain
in the X0=Off state.
If results in the form of (, ), or * are needed, they can be obtained by series and
parallel connection of M10-M12.
Please use the RST or ZRST command to clear the result.
Word device
H
KnX KnY KnM
T
or S
1
Comparison of binary floating point numbers
16-bit command
C
D
32-bit command (13 STEP)
DECMP
Continuous
execution type
Flag signal: none
designates a constant K or H, the command will
2
16-70
DECMPP
Pulse
execution type
: Comparison of
2