Delta C2000 Series User Manual page 209

Classical field oriented control ac motor drive
Hide thumbs Also See for C2000 Series:
Table of Contents

Advertisement

Chapter 10 Digital Keypad C2000 Series
7.
Multi-state bitmap
the bit's property value of the PLC. It defines what image or wording is when this bit is 0 or when this bit is 1.
Set the initial status to be 0 or 1 to define the displayed image or wording.
8.
Unit Measurement
Open a new file and double click on that window, you will see the following
Choose from the drop down list the Metrology and the Unity Name that you need.
As for Metrology, you have the following choices Length, Square Measure, Volume/Solid Measure,
Weight, Speed, Time and Temperature. The unit name changes automatically when you change
metrology type.
9.
Numeric Input Setting
This menu allows you to provide parameters or communication ports and to input numbers.
Click once on this button
Open a new file and double click on that window, you will see the following:
h.
Related Device: There are two blank spaces to fill in, one is <Write> and another one is <Read>.
Input the numbers that you want to display and the corresponding numbers of a parameter and that
of a communication port. For example, input 012C to Read and Write Parameter P01-44.
i.
OutLine Setting: The Frame setting, Font setting, Vertical Alignment and Horizontal Alignment are
the same as mentioned before. Click on the drop down menu and choose the setting that you need.
j.
Function key: The setting here allows you to program keys on the keypad. Press the key on the
menu then the corresponding key on the keypad will start to blink, then press Enter to confirm the
setting.
k.
Value Type & Value Length: These two factors influence the range of the Minimum and Maximum
Value of the Limit Setting. Please note that the corresponding supporting values for C2000 have to
be 16bits. The 32bits values are not supported.
l.
Value Setting: This part is set automatically by the keypad itself.
m.
Limit Setting: Input the range the security setting here.
: The setup window of the multi-state is shown as the image below. This object reads
: Click once on this Button:
:
.
10-34

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents