Chapter 7 Optional Accessories
Frame E
Applicable model
VFD450C23A/23E; VFD550C23A/23E; VFD750C23A/23E; VFD900C43A/43E; VFD1100C43A/43E;
Model MKC-EFKM1 Heat Sink Fan
1.
Loosen screw 1~4 (figure 1) and disconnect fan power
and pull out the fan. (As shown in the enlarged picture 3)
Screw1~4 Torque : 24~26kgf-cm (20.8~22.6lb-in)
1
2
3
4
Model MKC-EFKB Capacitor Fan
1.
Loosen screw 1~2 (figure 3) and disconnect fan power and pull out the fan. (As shown in the enlarged picture 3)
Screw1~2 Torque : 24~26kgf-cm (20.8~22.6lb-in)
Frame F
Applicable model
VFD900C23A/23E; VFD1320C43A/43E; VFD1600C43A/43E;
Fan model MKC-FFKM Heat Sink Fan
Loosen the screws and plug out the power of fan before removing (figure 1). Screw torque: 12~15kg-cm (10.4~13Ib-in)
C2000 Series
Figure 1
1
4
Model MKC-EFKM2 Heat Sink Fan
1.
Loosen screw 1~4 (figure 2) and disconnect fan power
and pull out the fan. (As shown in the enlarged picture 3)
Screw1~4 Torque : 24~26kgf-cm (20.8~22.6lb-in)
1
2
Figure 3
3
2
Figure 1
7-38
3
4
Figure 2
1
2

Hide quick links: