Delta C2000 Series User Manual page 410

Classical field oriented control ac motor drive
Hide thumbs Also See for C2000 Series:
Table of Contents

Advertisement

Content
Register
211BH
211FH High byte: decimal of current value (display)
2200H
2201H Display counter value (c)
2202H Actual output frequency XXXXXHz
2203H DC-BUS voltage XXX.XV
2204H Output voltage XXX.XV
2205H Power angle XXX.X
2206H Display actual motor speed kW of U, V, W XXXXXkW
2207H
2208H
2209H Display PG feedback (as Pr. 00-04 NOTE 1)
220AH PID feedback value after enabling PID function XXX.XX%
220BH
220CH
220DH
220EH IGBT temperature of drive power module
220FH The temperature of capacitance
2210H
2211H
2212H The multi-step speed that is executing (S)
2213H
2214H
2215H
2216H Pulse input frequency (PG2 of PG card) XXX.XXHz
2217H
2218H Position command tracing error
2219H Display times of counter overload XXX.XX%
221AH GFF XXX.XX%
221BH DCbus voltage ripples XXX.XV
221CH PLC register D1043 data (C)
221DH Pole of Permanent Magnet Motor
221EH User page displays the value in physical measure
221FH Output Value of Pr.00-05 XXX.XXHz
Chapter 12 Description of Parameter Settings C2000 Series
Max. opeartion frequency (Pr.01-00) or Max. user defined
value (Pr.00-26)
When Pr00-26 is 0, this value is equal to Pr01-00 setting
When Pr00-26 is not 0, and the command source is Keypad,
this value = Pr00-24 * Pr00-26 / Pr01-00
When Pr00-26 is not 0, and the command source is 485, this
value = Pr09-10 * Pr00-26 / Pr01-00
Display output current (A). When current is higher than
655.35,it will shift decimal as XXX.XA . The decimal can refer
to High byte of 211F.
Display motor speed in rpm estimated by the drive or encoder
feedback XXXXXrpm
Display positive/negative output torque in %, estimated by the
drive (t0.0: positive torque, -0.0: negative torque) XXX.X%
Display signal of AVI analog input terminal, 0-10V corresponds
to 0.00~100.00% (1.) (as Pr. 00-04 NOTE 2)
Display signal of ACI analog input terminal, 4-V20mA/0-10V
corresponds to 0.00~100.00% (2.) (as Pr. 00-04 NOTE 2)
Display signal of AUI analog input terminal, -10V~10V
corresponds to -100.00~100% (3.) (as Pr. 00-04 NOTE 2)
The status of digital input (ON/OFF), refer to Pr.02-12 (as Pr.
00-04 NOTE 3)
The status of digital output (ON/OFF), refer to Pr.02-18 (as Pr.
00-04 NOTE 4)
The corresponding CPU pin status of digital input (d.) (as Pr.
00-04 NOTE 3)
The corresponding CPU pin status of digital output (O.) (as Pr.
00-04 NOTE 4)
Number of actual motor revolution (PG1 of PG card) (P.) it will
start from 9 when the actual operation direction is changed or
keypad display at stop is 0. Max. is 65535
Pulse input position (PG card PG2), maximum setting is
65535.
12-09-10
Function
XXX.X
XXX.X

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents