of times they can be used in a program is unrestricted. Users can use an auxiliary relay M to
configure the control circuit, but cannot use it to directly drive an external load. Auxiliary relays have
the following two types of characteristics:
Ordinary auxiliary relays: Ordinary auxiliary relays will all revert to the Off state if a power outage
occurs while the PLC is running, and will remain in the Off state if power is again
turned down.
Special purpose auxiliary relays: Each special purpose auxiliary relay has its own specific use. Do not
use any undefined special purpose auxiliary relays.
Timer functions
Timers take 100 ms as their timing units. When the timing method is an upper time limit, when the
current timer value = set value, power will be sent to the output coil. Timer setting values consist of
decimal K values, and the data register D can also serve as a setting value.
Actual timer setting time = timing units * set value
Counter features
Item
Type
CT Direction:
Setting
0~32,767
Designation of
Constant K or data register D
set value
Change in current
When the count reaches the set value, there is no
value
longer a count
When the count reaches the set value, the contact
Output contact
comes On and stays On
Reset
The current value reverts to 0 when an RST
command is executed, and the contact reverts to Off
Contact actuation All are actuated after the end of scanning
Counter functions
When a counter's counting pulse input signal goes Off On, if the counter's current value is equal to
the set value, the output coil will come On. The setting value will be a decimal K values, and the data
register D can also serve as a setting value.
16-bit counter C0-C79:
16-bit counter setting range: K0-K32,767. (when K0 and K1 are identical, the output contact will
immediately be On during the first count.)
The current counter value will be cleared from an ordinary counter when power is shut off to the
PLC.
If the MOV command or WPLSoft is used to transmit a value greater than the set value to the
C0 current value register, when the next X1 goes from Off On, the C0 counter contact will
change to On, and the current value will change to the set value.
A counter's setting value may be directly set using a constant K or indirectly set using the value
in register D (not including special data registers D1000- D1199
If the set value employs a constant K, it may only be a positive number; the set value may be
either a positive or negative number if the value in data register D is used. The current counter
value will change from 32,767 to -32,768 as the count continues to accumulate.