Delta C2000 Series User Manual page 573

Classical field oriented control ac motor drive
Hide thumbs Also See for C2000 Series:
Table of Contents

Advertisement

API
INT
129
D
P
Bit device
X
Y
M
K
S
D
Notes on operand usage:
Please refer to the function specifications table for each device in
series for the scope of device usage
When X0=On, the binary floating point number (D1, D0) is transformed into a
BIN whole number, and the result is stored in (D10); the BIN whole number
floating point number will be discarded.
Word device
H
KnX KnY KnM
T
S: the source device to be transformed. D: results of transformation.
The content of the register designated by S is transformed from a binary
floating point number format into a BIN whole number, and is temporarily
stored in D. The BIN whole number floating point number will be discarded.
The action of this command is the opposite of that of command API 49
(FLT).
X0
16-81
Binary floating point number
number transformation
16-bit command
C
D
32-bit command (9 STEP)
DINT
Continuous
execution type
Flag signal: none
DINT
PLC Function Applications
BIN whole
DINTP
Pulse
execution type
D0
D10