Delta C2000 Series User Manual page 688

Classical field oriented control ac motor drive
Hide thumbs Also See for C2000 Series:
Table of Contents

Advertisement

Settings
Functions
66
SO Logic A output
68
SO Logic B output
C2000 factory setting Pr02-17(MO2)=66(N.O.) and Multi-function Output setting item has add
2 new function: 66 and 68.
Content of Multi-function Display
00-04=45
20-5 Operating sequence description
20-5-1Normal operation status
As shown in Figure 3: When the STO1~SCM1 and STO2~SCM2=ON (no STO function is need),
the drive will execute "Operating" or "Output Stop" according to RUN/STOP command.
RUN c ommand
STO1~ SCM1
s tatu s
STO2 ~SCM2
s tatu s
Driv e out put
Safety Output Normal Open
Safety Output Normal Close
Drive status
(MO=66)
Normal run
STO
STL1~STL3
45: Hardware version
Hardware version
RUN
ON(no S TO f unct ion n eed Pr0 6-44=0 )
ON(no S TO f unct ion n eed Pr0 6-44=0 )
Operat ing
Descriptions
Safety Output status
N.O.
N.C.
(MO=68)
Open
Close
Close
Open
Close
Open
STOP
Out put Stop
Figure 3
Factory setting: 3
Page 5/8