Classical field oriented control ac motor drive
Hide thumbs Also See for C2000 Series:
Table of Contents

Advertisement

5. Set ASR Parameters
Pr11-00 bit0=1:
Pr11-02
ASR1/ASR2 Switch Frequency
10Hz.
Pr11-03
ASR1 Low-speed Bandwidth
Low-speed Bandwith too high to avoid dissipation of the estimator.
6. Set speed estimator and speed control's parameter.
Pr10-39
Frequency when switch from I/F Mode to PM sensorless mode.
Pr10-32
PM Sensorless Obeserver Bandwith for High Speed Zone
7. Zero-load test
Refer to switch point prodcedure of I/F and FOC as shown in the image below.
Big variation of current or
OC while switching
Lower Per Unit of System
Inertia (Pr.11-01)/
Lower ASR1 Low-speed
Bandwidth (Pr.11-03)
Big variation of output
frequency or dissipation
IncreasePM Sensorless
Observer Bandwidth for
High Speed Zone (Pr.10-32)/
Decrease Per Unit of
System Inertia (Pr.11-01)
Chapter 12 Description of Parameter Settings C2000 Series
Auto tuning for ASR and APR
and Pr11-03,
Set frequency command
(Higher than switching command)
Perform RUN command
Can the drive run
NO
normally until switching
to higher frequency?
When running at high
NO
frequency, is the frequency
stable?
Increase load and Test
Procedure for switching between I
F mode and FOC mode
12-10-9
, it is recommended to set Pr10-39 higher than
ASR2 High-speed Bandwidth. Do not set
Observe output current
fequency via
Yes
commnucation intreface
Observe output current
fequency via
Yes
commnucation intreface