Delta C2000 Series User Manual page 227

Classical field oriented control ac motor drive
Hide thumbs Also See for C2000 Series:
Table of Contents

Advertisement

Pr.
Explanation
Output frequency setting
02-34
for multi-function output
terminal
External Operation Control
02-35
Selection after Reset and
Activate
02-47
Zero-speed Level of Motor
Max. Frequency of Resolution
02-48
Switch
Switch the delay time of Max.
02-49
output frequency
Status of Multi-function Input
02-50
Terminal
Status of Multi-function Output
02-51
Terminal
Display External Output terminal
02-52
occupied by PLC
Display Analog Input Terminal
02-53
occupied by PLC
Display the Frequency
02-54
Command Executed by External
Terminal
02-55
Reserved
02-56
Reserved
Multi-function output terminal:
02-57
Function 42: Brake Current
Checking Point
Multi-function output terminal:
02-58
Function 42: Brake Frequency
Checking Point
02-59
~
Reserved
02-69
02-70
IO card types
Chapter 11 Summary of Parameter Settings C2000 Series
Settings
0.00~600.00Hz Motor speed when using PG Card
0: Disable
1: Drive runs if run command exists after reset
0~65535 rpm
0.01~600.00Hz
0.000~65.000 sec.
Monitor the status of multi-function input terminals
Monitor the status of multi-function output terminals
Monitor the status of PLC input terminals
Monitor the status of PLC output terminals
Read only
0~150%
0.00~655.35Hz
0 NO IO card
1 EMC-BPS01
2 NO IO card
3 NO IO card
4 EMC-D611A
5 EMC-D42A
6 EMC-R6AA
7 NO IO card
11-13
Factory
Setting
0.00
0
0
60.00
0.000
Read
only
Read
only
Read
only
Read
only
Read
only
0
0.00
Read
only