Status 4: Motor drive is in stop; Pr06-48 0 ; Pr07-02=0
When motor drive starts, it will perform Pr06-48 as DC brake. The DC brake current level is 20
times of Pr06-47 setting value. In this period, if OPHL happens, motor drive starts to count until
Pr06-48/2, motor drive will perform Pr06-45 setting.
Sta tus 4-1: P r0 6-48 0, Pr07 -0 2=0 (N o OPH L d etected b efore op eratio n)
Operation command
OP HL de tec tion action
O PHL detection
20 *[P r06-47 ]
O utput current
Sta tus 4-2: P r0 6-48 0, Pr07 -0 2=0 (OPHL d e tected be fore ope ra tion )
Operation command
OP HL de tection action
OPHL dete ction
2 0 *[P r 0 6 - 47 ]
O utput current
Reserved
Time for Input Phase Loss Detection
Settings
0.00~600.00 sec
Chapter 12 Description of Parameter Settings C2000 Series
Drive 's st atus
O PHL detec tion acts
P r. 06- 47
Pr.06- 48
Total DC brak e time
Drive's statu s
O PHL detection acts
OPHL det ect ed
DC brak e c ommand
Actual output c urrent
P r.06 -47
Pr. 06-48
2
Pr.06 -48
Total DC brak e time
12-06-19
No OPHL detected
Start to operate
When OPHL, Pr06-45 acts
Time
Time
Factory Setting:0.20