Chapter 12 Description of Parameter Settings C2000 Series
Bit 7=0: frequency is saved before power turns off. When power turns on again, the display
frequency will be the memorized frequency.
Bit 7=1: frequency is not saved before power turns off. When power turns ON again, the display
frequency will be 0.00Hz.
Bit 8=0: maximum speed for point-to-point position control is control by the setting of Pr.11-43.
Bit 8=1: maximum speed for point-to-point position control is control by the multi-step speed
setting of the external terminal device. When multi-step speed of the external device is set to 0,
the maximum operation speed will bet the setting of Pr.11-43.
Per Unit of System Inertia
Settings
To get the system inertia from Pr.11-01, user needs to set Pr.11-00 to bit1=1 and execute
continuous forward/reverse running.
Unit of induction motor system inertia is 0.001kg-m^2:
Power
1HP
2HP
3HP
5HP
7.5HP
10HP
15HP
The base value for induction motor system inertia is set by Pr.05-38 and the unit is in 0.001kg-m^2.
ASR1/ASR2 Switch Frequency
Settings
ASR1 Low-speed Bandwidth
Settings
1~65535 256=1PU
Setting
Power
2.3
20HP
4.3
25HP
8.3
30HP
14.8
40HP
26.0
50HP
35.8
60HP
74.3
75HP
5.00~600.00Hz
1~40Hz (IM)/ 1~100Hz (PM)
Setting
95.3
142.8
176.5
202.5
355.5
410.8
494.8
12-11-2
Factory Setting: 400
Power
Setting
100HP
1056.5
125HP
1275.3
150HP
1900.0
175HP
2150.0
215HP
2800.0
300HP
3550.0
Factory Setting: 7.00
Factory Setting: 10