5.4 Calibration movement directions for all axes

Overview
When calibrating, the axis must consistently be run towards the calibration position
in the same direction in order to avoid position errors caused by backlash in gears
and so on. Positive directions are shown in the graphic below.
This is normally handled by the robot calibration software.
Calibration movement directions, 6 axes
Note! The graphic shows an IRB 7600. The positive direction is the same for all
6-axis robots, except the positive direction of axis 3 for IRB 6400R, which is in the
opposite direction!
xx0200000089
3HAC022033-001 Revision: M
© Copyright 2007-2013 ABB. All rights reserved.
5 Calibration information
5.4 Calibration movement directions for all axes
391