ABB IRB 7600 - 500/2.55 Product Manual page 138

Irb 7600 series
Hide thumbs Also See for IRB 7600 - 500/2.55:
Table of Contents

Advertisement

2 Installation and commissioning
2.6.5 Installation of position switches (option)
Continued
6
7
8
Continues on next page
138
Action
Connect the connector R3.FAN2 to the fan
of either axis 1 or axis 2.
If no fan is used, strap the cabling together
with the motor cabling so that the connector
stays close to the frame, as shown in the
figure to the right.
Run the remaining cable harness up through
the lower arm and:
secure with the bracket, lower arm,
as shown in the figure to the right.
connect the connector R2.SW3 to the
position switch of axis 3.
secure the cable going to the fan of
axis 3, together with the robot cabling
with a velcro strap.
Secure the axis 3 fan cable with the bracket,
upper arm.
© Copyright 2007-2013 ABB. All rights reserved.
Note
xx0500002312
xx0500002313
A Bracket, lower arm. Also shown in
the figure
Cable harness for posi-
tion switches and fans, axes 1-3 on
page
136.
B Bracket for robot cabling
C Connector R2.SW3
D Velcro strap
Shown in the figure
Cable harness for
position switches and fans, axes 1-3 on
page
136.
3HAC022033-001 Revision: M

Advertisement

Table of Contents
loading

Table of Contents