ABB IRB 7600 - 500/2.55 Product Manual page 116

Irb 7600 series
Hide thumbs Also See for IRB 7600 - 500/2.55:
Table of Contents

Advertisement

2 Installation and commissioning
2.5.12 Installation of cooling fan for motors, axes 1-3 (option)
Continued
7
8
9
10
11
Adjustments in RobotWare
1
116
Action
Secure the cable bracket to the bracket of the ro-
bot cabling inside the frame.
Run the cable underneath the robot cabling and
out through the side of the frame, at motor, axis
1 . The correct cable run is shown in the figure to
the right!
Note
There is a risk of the balancing device damaging
the cable if it is not protected by the robot cabling!
Connect the connector R3.FAN2 to the fan of axis
1 or 2.
Connect the connector R1.SW2/3 to the base of
the robot. Make sure that the cabling, run through
the frame and base, is not twisted and runs freely
from the robot cabling.
Refit the rear cover plate to the robot base.
Install additional cabling to and inside the control-
ler.
Also make adjustments in RobotWare, as de-
scribed in the following procedure.
Action
Modify the settings in RobotWare to
include the cooling fans.
© Copyright 2007-2013 ABB. All rights reserved.
Note
xx0500002174
A Cable bracket. Also shown
in the figure
cabling for axis 1 or 2 on
page
114.
Note
Fans on both axis 1 and 2 can not
be used at the same time!
Cabling is specified in section
sition switch cables, robot base to
controller (option) on page
Note
RobotWare 4.0: modify the settings in RobIn-
stall. RobotWare 4.063 and older must be up-
dated with a newer release.
RobotWare 5.0: change the settings in the
Modifying options dialogue, by using the
Modify Controller System Wizard in the Sys-
tem Builder of RobotStudio. Read more about
modifying the system in Operating manual -
RobotStudio.
3HAC022033-001 Revision: M