ABB IRB 7600 - 500/2.55 Product Manual page 168

Irb 7600 series
Hide thumbs Also See for IRB 7600 - 500/2.55:
Table of Contents

Advertisement

3 Maintenance
3.3.6 Inspection, oil level gearbox axis 6
Continued
5
6
7
8
168
Action
Measure the oil level (measurement a in the figure to
the right).
The required oil level depends on where the oil plug
is located on the tilthouse (shown in the figure to the
right).
Location A: required oil level: 40 mm ± 5 mm.
Location B: required oil level: 65 mm ± 5 mm.
Add oil if required.
Refit the oil plug, filling.
WARNING
Do not mix oil types! If wrong oil is refilled, the gearbox
must be rinsed as detailed in Technical reference
manual - Lubrication in gearboxes.
© Copyright 2007-2013 ABB. All rights reserved.
Note
xx0500002222
xx0600002737
Where to find type of oil and
total amount is detailed in
and amount of oil in gearboxes
on page
194.
Detailed in section
Oil change,
gearbox axis 6 on page
211.
Tightening torque: 24 Nm.
3HAC022033-001 Revision: M