Settings
Functions
66
SO Logic A output
68
SO Logic B output
C2000 factory setting Pr02-17(MO2)=66(N.O.) and Multi-function Output setting item
has add 2 new function: 66 and 68.
Content of Multi-function Display
00-04=45
17-5 Operating sequence description
17-5-1Normal operation status
As shown in Figure 3: When the STO1~SCM1 and STO2~SCM2=ON (no STO function is
need), the drive will execute "Operating" or "Output Stop" according to RUN/STOP
command.
RUN command
STO1~ SCM1
statu s
STO2 ~SCM2
statu s
Drive out put
Safety Output Normal Open
Safety Output Normal Close
Drive status
(MO=66)
Normal run
STO
STL1~STL3
45: Hardware version
Hardware version
RUN
ON(no S TO f unct ion n eed
ON(no S TO f unct ion n eed
Operat ing
Chapter 17 Safety Torque Off Function
Descriptions
Safety Output status
N.O.
N.C.
(MO=68)
Open
Close
Close
Open
Close
Open
STOP
Out put Stop
Figure 3
17-5
C2000 Series
Factory setting: 3
Pr0 6-44=0 )
Pr0 6-44=0 )