Delta C2000 Series User Manual page 538

Vector control drive
Hide thumbs Also See for C2000 Series:
Table of Contents

Advertisement

Command
PLS
Upper differential output
X0~X17
Operand
Upper differential output commands. When X0=Off On (positive edge-triggered), the
PLS command will be executed, and M0 will send one pulse, with a pulse length
consisting of one scanning period.
Ladder diagram:
X0
M0
Time sequence diagram:
X0
Time for one scan cycle
M0
Y0
Command
PLF
Lower differential output
X0~X17
Operand
Lower differential output command. When X0= On Off (negative edge-triggered), the
PLF command will be executed, and M0 will send one pulse, with pulse length
consisting of one scanning period.
Ladder diagram:
X0
M0
Time sequence diagram:
X0
Time for one scan cycle
M0
Y0
Command
END
Program conclusion
Operand
An END command must be added to the end of a ladder diagram program or
command program. The PLC will scan from address 0 to the END command, and will
return to address 0 and begins scanning again after execution.
Chapter 16 PLC Function Applications
Y0~Y17
M0~M799
M0
PLS
Y0
SET
Y0~Y17
M0~M799
M0
PLF
Y0
SET
16-47
Function
T0~159
C0~C79
Command code:
LD
X0
PLS
M0
LD
M0
SET
Y0
Function
T0~159
C0~C79
Command code:
LD
X0
PLF
M0
LD
M0
SET
Y0
Function
N/A
C2000 Series
D0~D399
Description:
Load Contact a of X0
M0 Upper differential
output
Load Contact a of M0
Y0 Action continues
(ON)
D0~D399
Description:
Load Contact a of X0
M0 Lower differential
output
Load Contact a of M0
Y0 Action continues
(ON)