Chapter 11 Summary of Parameter Settings
Pr.
00-04
Content of Multi-function Display
Coefficient Gain in Actual Output
00-05
Frequency
00-06
Software Version
Explanation
Settings
0: Display output current (A) (Unit: Amps)
1: Display counter value (c) (Unit: CNT)
2: Display actual output frequency (H.) (Unit: Hz)
3: Display DC-BUS voltage (v) (Unit: Vdc)
4: Display output voltage (E) (Unit: Vac)
5: Display output power angle (n) (Unit: deg)
6: Display output power in kW (P) (Unit: kW)
7: Display actual motor speed rpm (r) (Unit: rpm)
8: Display estimate output torque % (t) (Unit: %)
9: Display PG feedback (G) (refer to Pr.10-00,10-01)
(Unit: PLS)
10: Display PID feedback (b) (Unit: %)
11: Display AVI in % (1.) (Unit: %)
12: Display ACI in % (2.) (Unit: %)
13: Display AUI in % (3.) (Unit: %)
14: Display the temperature of IGBT in
)
15: Display the temperature of capacitance in
(c.) (Unit:
)
16: The status of digital input (ON/OFF) (i)
17: The status of digital output (ON/OFF) (o)
18: Multi-step speed (S)
19: The corresponding CPU pin status of digital
input (d)
20: The corresponding CPU pin status of digital
output (0.)
21: Actual motor position (PG1 of PG card) (P.)
22: Pulse input frequency (PG2 of PG card) (S.)
23: Pulse input position (PG2 of PG card) (q.)
24: Position command tracing error (E.)
25: Overload count (0.00~100.00%) (o.) (Unit: %)
26: Ground Fault GFF(G.) (Unit: %)
27: DC Bus voltage ripple (Unit: Vdc) (r.)
28: Display PLC data D1043 (C)
29: Display PM motor pole section (EMC-PG01U
application) (4.)
30: Display output of user defined (U)
31: Display Pr.00-05 user Gain(K)
32: Number of actual motor revolution during
operation (PG card plug in and Z phase signal
input) (Z.)
33: Motor actual position during operation (when PG
card is connected)(q)
34: Operation speed of fan (F.) (Unit: %)
35: Control Mode display: 0= Speed control mode
(SPD), 1= torque control mode (TQR) (t.)
36: Present operating carrier frequency of drive (Hz)
(J.)
37: Reserved
38: Display drive status (6.)
39: Display estimated output torque, positive and
negative, using Nt-m as unit (t 0.0: positive
torque; -0.0: negative torque (C.)
40: Torque Command (L) (Unit: %)
41: KWH display (J) (Unit: kWH)
42: PID Reference (h.) (Unit: %)
43: PID offset (o.) (Unit: %)
44: PID Output Fcmd(Hz) (b.) (Unit: Hz)
45: Hardware ID
0~160.00
Read only